{"title":"Indoor Air Quality 2027 — Regulation Compliant Equipment","description":"\u003cdiv class=\"vtuf-hub-page\" style=\"max-width:960px;margin:0 auto;font-family:'Barlow',-apple-system,sans-serif;color:#1a1a1a;line-height:1.6;font-size:1.05rem\"\u003e\n\u003cp style=\"background:#000;color:#FFBA00;font-family:'Oswald',sans-serif;font-weight:700;text-transform:uppercase;letter-spacing:0.08em;font-size:1rem;padding:0.85rem 1rem;margin-bottom:1.2rem;\"\u003eIndoor Air Quality 2027 — The Regulatory Framework and the Equipment Specification\u003c\/p\u003e\n\n\u003cp\u003eThree pieces of legislation are converging to create the UK's first framework of enforceable indoor air quality standards. The UK Indoor Air Quality Strategy, the Environment Act 2021 and Approved Document F (March 2027) together create mandatory measurable standards for air quality in workplaces, social housing and public buildings. HHSRS 2026 Hazard 18 and Awaab's Law Phase 2 (30 November 2026) are already in force. The equipment specification decisions are being made now.\u003c\/p\u003e\n\n\u003cp\u003eBrowse by equipment type:\u003c\/p\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:1rem;margin:1.2rem 0\"\u003e\n\u003cdiv style=\"background:#f5f5f5;padding:1.2rem;border-left:5px solid #FFBA00\"\u003e\n\u003cstrong style=\"display:block;font-family:'Oswald',sans-serif;font-size:1.1rem;margin-bottom:0.5rem\"\u003e\u003ca href=\"\/collections\/iaq-2027-h-class-extraction\" style=\"color:#000;text-decoration:none\"\u003eH-Class Extraction →\u003c\/a\u003e\u003c\/strong\u003e\n\u003cspan style=\"font-size:0.9rem;color:#555\"\u003eGRINDEX, MIDI HSV, MAXi and RUCKVAC HSV. 99.995% H14 HEPA. For mould remediation, post-construction cleaning and healthcare environments.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f5f5f5;padding:1.2rem;border-left:5px solid #FFBA00\"\u003e\n\u003cstrong style=\"display:block;font-family:'Oswald',sans-serif;font-size:1.1rem;margin-bottom:0.5rem\"\u003e\u003ca href=\"\/collections\/iaq-2027-aeromax-air-scrubbers\" style=\"color:#000;text-decoration:none\"\u003eAEROMAX Air Scrubbers →\u003c\/a\u003e\u003c\/strong\u003e\n\u003cspan style=\"font-size:0.9rem;color:#555\"\u003eContinuous ambient HEPA filtration for occupied buildings. 400CFM to 1200CFM. The ambient IAQ 2027 compliance tool for facilities management and remediation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f5f5f5;padding:1.2rem;border-left:5px solid #FFBA00\"\u003e\n\u003cstrong style=\"display:block;font-family:'Oswald',sans-serif;font-size:1.1rem;margin-bottom:0.5rem\"\u003e\u003ca href=\"\/collections\/iaq-2027-m-class-occupied-buildings\" style=\"color:#000;text-decoration:none\"\u003eM-Class for Occupied Buildings →\u003c\/a\u003e\u003c\/strong\u003e\n\u003cspan style=\"font-size:0.9rem;color:#555\"\u003eMINI HSV, MIGHTY HSV, RUCKVAC-ION and GRINDEX1100LP. 99.9% filtration for general occupied building cleaning under IAQ 2027.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-family:'Oswald',sans-serif;font-weight:700;text-transform:uppercase;font-size:1.4rem;border-left:5px solid #FFBA00;padding-left:0.85rem;margin:1.2rem 0 0.6rem\"\u003eThe three regulatory pillars\u003c\/h2\u003e\n\u003cul style=\"padding-left:1.4rem;margin:0 0 0.85rem\"\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eUK Indoor Air Quality Strategy\u003c\/strong\u003e — mandatory measurable standards for indoor air pollutant levels in public, commercial and residential buildings\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eEnvironment Act 2021\u003c\/strong\u003e — legally binding air quality targets extending regulation indoors\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eApproved Document F — March 2027\u003c\/strong\u003e — strengthened ventilation requirements for new buildings and material alterations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-family:'Oswald',sans-serif;font-weight:700;text-transform:uppercase;font-size:1.4rem;border-left:5px solid #FFBA00;padding-left:0.85rem;margin:1.2rem 0 0.6rem\"\u003eAlready in force\u003c\/h2\u003e\n\u003cul style=\"padding-left:1.4rem;margin:0 0 0.85rem\"\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eHHSRS 2026 Hazard 18\u003c\/strong\u003e — Indoor Air Pollutants: inspectable and enforceable from June 2026\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eAwaab's Law Phase 2\u003c\/strong\u003e — 30 November 2026 — extended to additional hazard categories\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eCOSHH 2002\u003c\/strong\u003e — mould (Hazard Group 2 biological agent), silica, wood dust already regulated\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-family:'Oswald',sans-serif;font-weight:700;text-transform:uppercase;font-size:1.4rem;border-left:5px solid #FFBA00;padding-left:0.85rem;margin:1.2rem 0 0.6rem\"\u003eSectors affected first\u003c\/h2\u003e\n\u003cul style=\"padding-left:1.4rem;margin:0 0 0.85rem\"\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eSocial housing\u003c\/strong\u003e — HHSRS 2026 and Awaab's Law already in force\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eHealthcare\u003c\/strong\u003e — NHS and ICRA already mandate HEPA filtration in clinical areas\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eEducation\u003c\/strong\u003e — CO2 monitoring already underway; particulate standards next\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eFacilities management\u003c\/strong\u003e — employer duty of care gains measurable enforceable IAQ standards\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\n\u003cstrong\u003eConstruction and refurbishment\u003c\/strong\u003e — Approved Document F material alteration trigger from March 2027\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul style=\"padding-left:1.4rem;margin:0 0 0.85rem\"\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/pages\/indoor-air-quality-regulation-2027\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eIndoor Air Quality Regulation 2027 — full legislation page →\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/collections\/awaabs-law-compliant-equipment\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eAwaab's Law compliant equipment →\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/blogs\/compliance-centre\/indoor-air-quality-2027-businesses-contractors-compliance\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eIAQ 2027 — what businesses and contractors need to do now →\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/pages\/legislation\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eFull legislation hub →\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eTelephone: \u003cstrong\u003e01522 787978\u003c\/strong\u003e for IAQ 2027 specification advice. \u003ca href=\"\/pages\/contact\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eContact the V-TUF trade team →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","products":[{"product_id":"vtuf-ruckvacion-hsv-300w-cordless-mclass-rated-backpack-vacuum-cleaner-with-lung-safe-hepa-filtration-battery-operated","title":"V-TUF RUCKVAC-ION 300W Cordless M-Class Backpack Vacuum Cleaner - H13 HEPA Filtration (Battery)","description":"\u003cp\u003e\u003cstrong\u003eV-TUF RUCKVAC-ION 300W Cordless M-Class Backpack Vacuum Cleaner H13 HEPA Filtration (RUCKVAC-ION)\u003c\/strong\u003e is a battery-operated M-Class backpack vacuum with H13 HEPA filtration, delivering cable-free M-Class dust extraction for construction trades and maintenance operatives working in awkward and restricted access environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction trades and maintenance operatives requiring M-Class extraction with complete cable-free mobility in lofts, staircases, scaffolding and elevated spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor power: 300W, cordless battery-operated\u003c\/li\u003e\n\u003cli\u003eBackpack harness: Hands-free operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRUCKVAC-ION machine with backpack harness\u003c\/li\u003e\n\u003cli\u003eBattery and charger\u003c\/li\u003e\n\u003cli\u003eHose, wand, and tool set\u003c\/li\u003e\n\u003cli\u003eM-Class H13 HEPA filter\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only — not rated for asbestos or H-Class hazards. For H-Class cordless see RUCKVACHSV-LI.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class minimum for most construction dust. Cordless format enables M-Class compliance in areas where trailing cables are impractical.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Dust control is a CDM duty. M-Class required for most dust-generating tasks.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — M-Class with water suppression for most silica tasks.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e See the \u003ca href=\"\/pages\/ruckvac-spare-parts\"\u003eRUCKVAC Spare Parts\u003c\/a\u003e page, or call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798340059476,"sku":"RUCKVAC-ION","price":939.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/RUCKVAC-ION_1_2.jpg?v=1779304465"},{"product_id":"vtuf-maxi-80l-hclass-240v-3500w-industrial-dust-extraction-vacuum-cleaner","title":"V-TUF MAXi 80L H-Class 3500w Industrial Dust Extraction Vacuum Cleaner - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eA high-capacity H-Class vacuum - ideal for large remediation and heavy-duty dust extraction.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MAXi 80L H-Class 240V 3500W Industrial Dust Extraction Vacuum Cleaner (MAXIH240-80L)\u003c\/strong\u003e is an 80-litre H-Class industrial vacuum on 240V mains — H-Class rated for the highest level of protection against carcinogens, asbestos fibres, mould, lead, and hazardous respirable particles. For 110V site use see MAXI80H-110. For 50L see MAXIH240-50L.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, refurbishment trades, and any environment requiring maximum-capacity H-Class extraction on 240V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA — 99.995% efficient\u003c\/li\u003e\n\u003cli\u003eMotor: 2000W, 240V | Tank: 80 litres stainless steel | Auto filter shaker | Velocity monitor | Hose: 5m × 38mm Hi-Viz anti-static\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAXi 80L 240V machine | 5m × 38mm Hi-Viz anti-static hose | Stainless steel wand set | Heavy duty floor head | Crevice tool | H-Class cartridge filter and Aqua-Dry basket filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag and filter changes. For asbestos work follow BS 8520-3:2009.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/motorsport-valley\"\u003eMotorsport Valley \u0026amp; composites\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class mandatory for all vacuum work involving asbestos dust. M-Class not permitted under any CAR 2012 work category.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class mandatory for Type C and D works in NHS hospitals and healthcare environments.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould, asbestos, carbon fibre and lead paint all require H-Class containment under COSHH.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — H-Class required wherever the COSHH assessment identifies hazardous dust.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — RCS WEL 0.1 mg\/m³. H-Class required in enclosed environments and wherever M-Class cannot reduce exposure to below the WEL.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798355624276,"sku":"MAXIH240-80L","price":1604.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MAXI-240-80L_1S_d5f973c0-1dce-4267-8263-92ed57097373.jpg?v=1780484401"},{"product_id":"vtuf-maxi-80l-hclass-110v-2500w-industrial-dust-extraction-vacuum-cleaner","title":"V-TUF MAXi 80L H-Class Industrial Dust Extraction Vacuum Cleaner - 110V (Transformer Required)","description":"\u003cp\u003e\u003cstrong\u003eA high-capacity H-Class vacuum — ideal for large remediation and heavy-duty dust extraction.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MAXi 80L H-Class 110V 2500W Industrial Dust Extraction Vacuum Cleaner (MAXI80H-110)\u003c\/strong\u003e is a maximum-capacity 80-litre H-Class industrial vacuum on 110V site-safe supply for extended high-volume hazardous dust extraction on the largest remediation and refurbishment projects. For 240V see MAXI80H-240. 110V requires site transformer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, and refurbishment trades on 110V site supply requiring maximum-capacity H-Class extraction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA | Power: 2500W twin motor, 110V | Tank: 80 litres | Dry only\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMAXi 80L 110V machine | Hose, wand, and floor tool set | H14 HEPA filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag changes. For asbestos work follow BS 8520-3:2009.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class mandatory for all vacuum work involving asbestos dust. M-Class not permitted under any CAR 2012 work category.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class mandatory for Type C and D works in NHS hospitals and healthcare environments.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould, asbestos and lead paint all require H-Class containment.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — H-Class required wherever COSHH assessment identifies hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/electricity-at-work-regulations\"\u003eElectricity at Work Regulations 1989\u003c\/a\u003e — 110V CTE mandated on UK construction sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56706700738900,"sku":"MAXIH110-80L","price":1604.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MAXI-RANGE-2023-FRONT-110V_eb976ace-1c6f-45a8-9735-d48b2b1f9aea.jpg?v=1780484401"},{"product_id":"vtuf-maxi-50l-hclass-240v-1750w-industrial-dust-extraction-vacuum-cleaner","title":"V-TUF MAXi 50L H-Class 1750w Industrial Dust Extraction Vacuum Cleaner - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eA high-capacity H-Class vacuum — ideal for large remediation and heavy-duty dust extraction.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MAXi 50L H-Class 240V 1750W Industrial Dust Extraction Vacuum Cleaner (MAXIH240-50L)\u003c\/strong\u003e is a 50-litre H-Class industrial vacuum on 240V mains — H-Class rated for the highest level of protection against carcinogens, asbestos fibres, formaldehyde, mould, lead, and hazardous respirable particles.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, refurbishment trades, and any environment where H-Class dust extraction is legally required on 240V mains.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA — 99.995% efficient\u003c\/li\u003e\n\u003cli\u003eMotor power: 1750W, 240V | Tank: 50 litres | Auto filter shaker | PTO | Hose: 5m × 38mm Hi-Viz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMAXi 50L 240V machine | 5m × 38mm Hi-Viz hose | Stainless steel wand set | Floor head and tools | Universal power tool adaptor | H-Class cartridge filter and Aqua-Dry basket filter\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag and filter changes. For asbestos work follow BS 8520-3:2009. For 110V see MAXIH110. For 80L see MAXI80H-240.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/motorsport-valley\"\u003eMotorsport Valley \u0026amp; composites\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class mandatory for all vacuum work involving asbestos dust. M-Class not permitted under any CAR 2012 work category.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class mandatory for Type C and D works in NHS hospitals and healthcare environments.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould, asbestos, carbon fibre and lead paint all require H-Class containment under COSHH.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — H-Class required wherever the COSHH assessment identifies hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — RCS WEL 0.1 mg\/m³. H-Class required in enclosed environments and wherever M-Class cannot reduce exposure to below the WEL.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798376759636,"sku":"MAXIH240-50L","price":855.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MAXIH240-50L_1S_d789c57f-fd37-48e0-8f2b-30fdc00927ea.jpg?v=1780124878"},{"product_id":"vtuf-maxi-50l-h-class-industrial-dust-extraction-vacuum-cleaner-110v-1750w","title":"V-TUF MAXi 50L H-Class Industrial Dust Extraction Vacuum Cleaner - 110V (Transformer Required)","description":"\u003cp\u003e\u003cstrong\u003eA high-capacity H-Class vacuum — ideal for large remediation and heavy-duty dust extraction.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MAXi 50L H-Class 110V 1750W Industrial Dust Extraction Vacuum Cleaner (MAXIH110)\u003c\/strong\u003e is a large-capacity 50-litre H-Class industrial vacuum on 110V site-safe supply for the highest level of dust protection against carcinogens, asbestos fibres, and hazardous respirable particles. For 240V see MAXIH240. For 80L see MAXI80H. 110V requires site transformer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, and refurbishment trades on 110V site supply requiring large-capacity H-Class extraction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA | Power: 1750W, 110V | Tank: 50 litres | Dry only\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMAXi 50L 110V machine | Hose, wand, and floor tool set | H14 HEPA filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag changes. For asbestos work follow BS 8520-3:2009.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/motorsport-valley\"\u003eMotorsport Valley \u0026amp; composites\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class mandatory for all vacuum work involving asbestos dust. M-Class not permitted under any CAR 2012 work category.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class mandatory for Type C and D works in NHS hospitals.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould, asbestos, carbon fibre and lead paint require H-Class containment.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — H-Class required wherever COSHH assessment identifies hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/electricity-at-work-regulations\"\u003eElectricity at Work Regulations 1989\u003c\/a\u003e — 110V CTE mandated on UK construction sites.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — RCS WEL 0.1 mg\/m³. H-Class required in enclosed environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56706697331028,"sku":"MAXIH110-50L","price":855.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MAXIH110-50L_1S_82aa6e43-458b-4138-94b2-b80ac75f89fd.jpg?v=1780486190"},{"product_id":"vtuf-mighty-hsv-21l-mclass-240v-industrial-dust-extraction-wet-dry-vacuum-cleaner-health-safety-version","title":"V-TUF MIGHTY HSV 21L M-Class Wet \u0026 Dry Dust Extraction Vacuum Cleaner - 1250W with Velocity Monitor - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eA wet and dry M-Class vacuum — ideal for site clean-down and general dust control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIGHTY HSV 21L M-Class Wet \u0026amp; Dry Dust Extraction Vacuum Cleaner 240V (MIGHTYHSV240)\u003c\/strong\u003e is a 21-litre M-Class wet and dry vacuum on 240V mains with velocity monitor for compliant dust extraction. For 110V see MIGHTYHSV110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction trades and workshops requiring M-Class wet and dry extraction on 240V mains supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor: 1250W, 240V | Tank: 21 litres wet \u0026amp; dry | Velocity monitor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMIGHTYHSV240 machine | Hose, wand set, floor tools | M-Class filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only. For H-Class see MIDIH240 or MIDIHSV240.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class minimum legal standard for most construction dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Dust control is a CDM duty on all construction projects.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — M-Class with water suppression is the specified control for most silica tasks.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/puwer\"\u003ePUWER 1998\u003c\/a\u003e — Work equipment must be suitable for purpose and maintained in safe condition.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798993191252,"sku":"MIGHTYHSV240","price":370.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIGHTYHSV240_1M.jpg?v=1779301008"},{"product_id":"vtuf-aeromax500240-air-filtration-cleaner-turbo-fan-240v-158w","title":"V-TUF AEROMAX500-240 Air Filtration Cleaner TURBO FAN, 158W - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eA wet and dry M-Class vacuum — ideal for site clean-down and general dust control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX500-240 Air Filtration Cleaner Turbo Fan 158W 240V (AEROMAX500-240)\u003c\/strong\u003e is a 240V mains air filtration unit for construction sites and healthcare environments, continuously filtering airborne respirable dust from enclosed working areas during refurbishment and remediation works. For 110V see AEROMAX500-110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction contractors working in occupied buildings, NHS hospital refurbishment teams, and any trade requiring airborne particulate control in enclosed spaces on 240V mains supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor: 158W turbo fan, 240V mains\u003c\/li\u003e\n\u003cli\u003eFunction: Continuous air filtration of enclosed working areas\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Air filtration is a supplementary control — not a substitute for on-tool M-Class or H-Class dust extraction at source.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — ICRA Type C and D works require engineering controls to prevent airborne fungal spores from reaching patient areas. Air filtration is a specified supplementary control in high patient-risk zones alongside H-Class on-tool extraction.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Airborne respirable dust in enclosed construction environments must be controlled by engineering controls. Air filtration supplements on-tool extraction and water suppression.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Principal contractors must ensure dust control in enclosed working areas protecting both workers and building occupants.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798994927956,"sku":"AEROMAX500-240","price":1271.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/Aeromax500-240_2.jpg?v=1779288351"},{"product_id":"vtuf-aeromax500110-air-filtration-cleaner-turbo-fan-110v-158w","title":"V-TUF AEROMAX500-110 Air Filtration Cleaner TURBO FAN, 158W - 110V (Transformer Required)","description":"\u003cp\u003e\u003cstrong\u003eA wet and dry M-Class vacuum — ideal for site clean-down and general dust control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX500-110 Air Filtration Cleaner Turbo Fan 158W 110V (AEROMAX500-110)\u003c\/strong\u003e is a 110V site-safe air filtration unit for construction sites and healthcare environments, continuously filtering airborne respirable dust from enclosed working areas during refurbishment and remediation works.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction contractors working in occupied buildings, NHS hospital refurbishment teams, and any trade requiring airborne particulate control in enclosed spaces on 110V site supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor: 158W turbo fan, 110V site-safe\u003c\/li\u003e\n\u003cli\u003eFunction: Continuous air filtration of enclosed working areas\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Air filtration is a supplementary control — not a substitute for on-tool M-Class or H-Class dust extraction at source. 110V requires site transformer.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — ICRA Type C and D works require engineering controls to prevent airborne fungal spores from reaching patient areas. Air filtration is a specified supplementary control in high patient-risk zones alongside H-Class on-tool extraction.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Airborne respirable dust in enclosed construction environments must be controlled by engineering controls. Air filtration supplements on-tool extraction and water suppression.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Principal contractors must ensure dust control in enclosed working areas protecting both workers and building occupants.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/electricity-at-work-regulations\"\u003eElectricity at Work Regulations 1989\u003c\/a\u003e — 110V CTE is the mandated supply for portable electrical equipment on UK construction sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798994993492,"sku":"AEROMAX500-110","price":1271.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/Aeromax500-110_2.jpg?v=1779288351"},{"product_id":"vtuf-mighty-xl-hsv-37l-mclass-110v-industrial-dust-extraction-wet-dry-vacuum-cleaner-health-safety-version","title":"V-TUF MIGHTY XL HSV 37L M-Class Wet \u0026 Dry Dust Extraction Vacuum Cleaner - 1250W with Velocity Monitor - 110V (Transformer Required)","description":"\u003cp\u003e\u003cstrong\u003eA wet and dry M-Class vacuum — ideal for site clean-down and general dust control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIGHTY XL HSV 37L M-Class Wet \u0026amp; Dry Dust Extraction Vacuum Cleaner 110V (MIGHTYXLHSV110)\u003c\/strong\u003e is a high-capacity 37-litre M-Class wet and dry vacuum on 110V site-safe supply with velocity monitor for sustained M-Class extraction on construction sites. For 240V see MIGHTYXLHSV240.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction trades on 110V site supply requiring high-capacity M-Class wet and dry extraction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor: 1250W, 110V | Tank: 37 litres wet \u0026amp; dry | Velocity monitor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMIGHTYXLHSV110 machine | Hose, wand set, floor tools | M-Class filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only. For H-Class see MIDIHSV110 or MIDI SYNCRO range. 110V requires site transformer.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class minimum for most construction dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Dust control is a CDM duty.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/electricity-at-work-regulations\"\u003eElectricity at Work Regulations 1989\u003c\/a\u003e — 110V CTE mandated on UK construction sites.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — M-Class with water suppression for most silica tasks.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799072620884,"sku":"MIGHTYXLHSV110","price":476.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIGHTYXLHSV110_1.jpg?v=1779301023"},{"product_id":"vtuf-mighty-xl-hsv-37l-mclass-240v-industrial-dust-extraction-wet-dry-vacuum-cleaner-health-safety-version","title":"V-TUF MIGHTY XL HSV 37L M-Class Wet \u0026 Dry Dust Extraction Vacuum Cleaner - 1250W with Velocity Monitor - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eA wet and dry M-Class vacuum — ideal for site clean-down and general dust control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIGHTY XL HSV 37L M-Class Wet \u0026amp; Dry Dust Extraction Vacuum Cleaner 240V (MIGHTYXLHSV240)\u003c\/strong\u003e is a high-capacity 37-litre M-Class wet and dry vacuum on 240V mains with velocity monitor for sustained M-Class extraction. For 110V see MIGHTYXLHSV110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction trades and workshops requiring high-capacity M-Class wet and dry extraction on 240V mains.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor: 1250W, 240V | Tank: 37 litres wet \u0026amp; dry | Velocity monitor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMIGHTYXLHSV240 machine | Hose, wand set, floor tools | M-Class filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only. For H-Class see MIDIHSV240 or MIDI SYNCRO range.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class minimum for most construction dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Dust control is a CDM duty.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — M-Class with water suppression for most silica tasks.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/puwer\"\u003ePUWER 1998\u003c\/a\u003e — Work equipment must be suitable for purpose and maintained in safe condition.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799073374548,"sku":"MIGHTYXLHSV240","price":481.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIGHTYXLHSV240_1.jpg?v=1779301019"},{"product_id":"vtuf-ruckvac-mclass-rated-cordless-backpack-vacuum-cleaner-battery-operated-extra-battery-pack-charger","title":"V-TUF RUCKVAC M-Class Rated Cordless Backpack Vacuum Cleaner - Battery Operated - EXTRA BATTERY PACK \u0026 CHARGER","description":"\u003cp\u003e\u003cstrong\u003eA cordless backpack vacuum — ideal for high-level cleaning and restricted access areas.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF RUCKVAC M-Class Cordless Backpack Vacuum Cleaner — Extra Battery Pack \u0026amp; Charger (RUCKVAC-ION-KIT4)\u003c\/strong\u003e bundles the RUCKVAC ION M-Class cordless backpack vacuum with an extra battery pack and charger for extended run-time on all-day maintenance programmes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Maintenance operatives and construction trades requiring extended battery life for all-day M-Class extraction without stopping to recharge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor: 300W, cordless\u003c\/li\u003e\n\u003cli\u003eIncludes extra battery pack and charger\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRUCKVAC-ION machine with backpack harness\u003c\/li\u003e\n\u003cli\u003eExtra battery pack and charger\u003c\/li\u003e\n\u003cli\u003eFilter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only. For H-Class see RUCKVACHSV-LI.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class minimum for most construction dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Dust control is a CDM duty.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799192551764,"sku":"RUCKVAC-ION-KIT4","price":1069.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/RUCKVAC-ION_Main_image.jpg?v=1779304464"},{"product_id":"vtuf-ruckvac-mclass-rated-cordless-backpack-vacuum-cleaner-battery-operated-extra-battery-packcharger-holdall","title":"V-TUF RUCKVAC M-Class Rated Cordless Backpack Vacuum Cleaner - Battery Operated \u0026 EXTRA BATTERY PACK,CHARGER \u0026 HOLDALL","description":"\u003cp\u003e\u003cstrong\u003eA cordless backpack vacuum — ideal for high-level cleaning and restricted access areas.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF RUCKVAC M-Class Cordless Backpack Vacuum Cleaner — Extra Battery Pack, Charger \u0026amp; Holdall (RUCKVAC-ION-KIT5)\u003c\/strong\u003e is the complete RUCKVAC ION M-Class cordless bundle with extra battery, charger and holdall for operatives on multi-site maintenance programmes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Maintenance operatives requiring a complete M-Class cordless extraction kit with extended battery life and storage for multi-site working.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor: 300W, cordless\u003c\/li\u003e\n\u003cli\u003eIncludes extra battery, charger and holdall\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRUCKVAC-ION machine with backpack harness\u003c\/li\u003e\n\u003cli\u003eExtra battery pack, charger and holdall\u003c\/li\u003e\n\u003cli\u003eFilter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only. For H-Class see RUCKVACHSV-LI.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class minimum for most construction dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Dust control is a CDM duty.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799192682836,"sku":"RUCKVAC-ION-KIT5","price":2101.03,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/RUCKVAC-ION_Main_image.jpg?v=1779304464"},{"product_id":"vtuf-midi-hsv-21l-hclass-110v-industrial-dust-extraction-vacuum-cleaner-asbestos-health-safety-version","title":"V-TUF MIDI HSV 21L ULPA15 Industrial Dust Extraction Vacuum Cleaner - Asbestos Rated with Velocity Monitor - 110V (Transformer Required)","description":"\u003cp\u003e\u003cstrong\u003eAn H-Class vacuum — ideal for mould, asbestos and hazardous dust environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIDI HSV 21L H-Class 110V Industrial Dust Extraction Vacuum Cleaner (MIDIHSV110)\u003c\/strong\u003e is a 21-litre H-Class industrial vacuum cleaner with ULPA15 filtration, capturing carcinogens, asbestos fibres, and the finest respirable dust particles with 99.9995% filtration efficiency. For 240V see MIDIHSV240.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, refurbishment trades, and any environment where H-Class dust extraction is legally required on 110V site supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: ULPA15 — 99.9995% efficiency on respirable particles\u003c\/li\u003e\n\u003cli\u003eMotor power: 1150W turbine motor, 110V \/ 50–60Hz\u003c\/li\u003e\n\u003cli\u003eTank capacity: 21 litres\u003c\/li\u003e\n\u003cli\u003eAir velocity: 40m\/sec (monitored at 20m\/sec)\u003c\/li\u003e\n\u003cli\u003eHose: 5m × 32mm Hi-Viz yellow\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e5m heavy duty yellow 32mm hose\u003c\/li\u003e\n\u003cli\u003e32mm stainless steel tubes and eKgow\u003c\/li\u003e\n\u003cli\u003e420mm wide floor head, upholstery tool, round brush, crevice tool\u003c\/li\u003e\n\u003cli\u003eUniversal power tool adaptor\u003c\/li\u003e\n\u003cli\u003ePack of 15L HEPA dust bags and coned filter basket\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Dry recovery only. For asbestos work, follow BS 8520-3:2009. H-Class machines require full PPE during filter and bag changes. 110V requires site transformer.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/motorsport-valley\"\u003eMotorsport Valley \u0026amp; composites\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class extraction is mandatory for all vacuum work involving asbestos dust across all three work categories. M-Class is not permitted for asbestos under any category.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class extraction is mandatory for Type C and D works in medium and high patient-risk zones inside NHS hospitals and healthcare facilities.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould spores, asbestos fibres, carbon fibre dust and lead paint particles are all biological or hazardous agents requiring H-Class containment under COSHH.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eConstruction Design and Management Regulations 2015 (CDM 2015)\u003c\/a\u003e — H-Class is required wherever the COSHH assessment identifies hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e — The RCS WEL of 0.1 mg\/m³ applies to all silica-generating operations. H-Class extraction is required in enclosed environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires for contractors in pre-2000 buildings →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eCAR 2012 explained: licensed, notifiable non-licensed and non-licensed asbestos work →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799285285204,"sku":"MIDIHSV110","price":962.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIDIHSV.jpg?v=1779300988"},{"product_id":"vtuf-midi-hsv-21l-hclass-240v-industrial-dust-extraction-vacuum-cleaner-asbestos-health-safety-version","title":"V-TUF MIDI HSV 21L ULPA15 Industrial Dust Extraction Vacuum Cleaner - Asbestos Rated with Velocity Monitor - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eAn H-Class vacuum — ideal for mould, asbestos and hazardous dust environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIDI HSV 21L H-Class 240V Industrial Dust Extraction Vacuum Cleaner (MIDIHSV240)\u003c\/strong\u003e is a 21-litre H-Class industrial vacuum cleaner with ULPA15 filtration, capturing carcinogens, asbestos fibres, and the finest respirable dust particles with 99.9995% filtration efficiency. For 110V see MIDIHSV110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, refurbishment trades, and any environment where H-Class dust extraction is legally required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: ULPA15 — 99.9995% efficiency on respirable particles\u003c\/li\u003e\n\u003cli\u003eMotor power: 1150W turbine motor, 240V\u003c\/li\u003e\n\u003cli\u003eTank capacity: 21 litres\u003c\/li\u003e\n\u003cli\u003eAir velocity: 40m\/sec (monitored at 20m\/sec)\u003c\/li\u003e\n\u003cli\u003eHose: 5m × 32mm Hi-Viz yellow\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e5m heavy duty yellow 32mm hose\u003c\/li\u003e\n\u003cli\u003e32mm stainless steel tubes and eKgow\u003c\/li\u003e\n\u003cli\u003e420mm wide floor head, upholstery tool, round brush, crevice tool\u003c\/li\u003e\n\u003cli\u003eUniversal power tool adaptor\u003c\/li\u003e\n\u003cli\u003ePack of 15L HEPA dust bags and coned filter basket\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Dry recovery only. For asbestos work, follow BS 8520-3:2009 Code of Practice. H-Class machines require full PPE during filter and bag changes.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/motorsport-valley\"\u003eMotorsport Valley \u0026amp; composites\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class extraction is mandatory for all vacuum work involving asbestos dust across all three work categories. M-Class is not permitted for asbestos under any category.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class extraction is mandatory for Type C and D works in medium and high patient-risk zones inside NHS hospitals and healthcare facilities.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould spores, asbestos fibres, carbon fibre dust and lead paint particles are all biological or hazardous agents requiring H-Class containment under COSHH.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eConstruction Design and Management Regulations 2015 (CDM 2015)\u003c\/a\u003e — H-Class is required wherever the COSHH assessment identifies hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e — The RCS WEL of 0.1 mg\/m³ applies to all silica-generating operations. H-Class extraction is required in enclosed environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires for contractors in pre-2000 buildings →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eCAR 2012 explained: licensed, notifiable non-licensed and non-licensed asbestos work →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799285416276,"sku":"MIDIHSV240","price":962.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIDIHSV.jpg?v=1779300988"},{"product_id":"vtuf-ruckvac-hsv-500w-cordless-hclass-rated-backpack-vacuum-cleaner-with-lung-safe-hepa-filtration-battery-operated","title":"V-TUF RUCKVAC HSV 500W Cordless H-Class Rated Backpack Vacuum Cleaner  with Lung-Safe HEPA Filtration (Battery Operated)","description":"\u003cp\u003e\u003cstrong\u003eA cordless backpack vacuum — ideal for high-level cleaning and restricted access areas.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF RUCKVAC HSV 500W Cordless H-Class Rated Backpack Vacuum Cleaner with Lung-Safe HEPA Filtration (RUCKVACHSV-LI)\u003c\/strong\u003e is a battery-operated H-Class rated backpack vacuum delivering cable-free H-Class dust extraction wherever power isn't available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, refurbishment trades, and social housing maintenance operatives requiring H-Class compliant dust extraction with complete cable-free freedom.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class rated HEPA — Lung-Safe filtration\u003c\/li\u003e\n\u003cli\u003eMotor power: 500W, cordless battery-operated\u003c\/li\u003e\n\u003cli\u003eBackpack harness: Hands-free operation\u003c\/li\u003e\n\u003cli\u003eNo trailing cables: Safe for all access environments\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRUCKVACHSV-LI machine with backpack harness\u003c\/li\u003e\n\u003cli\u003eBattery and charger\u003c\/li\u003e\n\u003cli\u003eHose, wand, and tool set\u003c\/li\u003e\n\u003cli\u003eHEPA filter\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class rated — PPE required during filter and bag changes. Check battery charge before starting extended work.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class rated extraction is appropriate for non-licensed and notifiable non-licensed CAR 2012 asbestos work. The cordless format is ideal for awkward pre-2000 building environments.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class rated extraction for Type C and D works in NHS hospitals and healthcare environments. Cordless operation removes the cable trip risk in patient areas.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — H-Class rated containment for mould spores, hazardous dust and biological agents in social housing and void property remediation.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e — H-Class extraction is required for mould remediation work in social housing under the Social Housing (Regulation) Act 2023.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/awaabs-law-social-housing-maintenance-contractors\"\u003eAwaab's Law: what it means for social housing maintenance contractors →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/damp-mould-void-properties-social-housing\"\u003eDamp and mould in void properties: H-Class and the correct remediation standard →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799372644692,"sku":"RUCKVACHSV-LI","price":1059.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/RUCKVACHSV-LI_1N.jpg?v=1779285726"},{"product_id":"vtuf-midi-syncro-21l-hclass-240v-industrial-dust-extraction-vacuum-cleaner-with-power-take-off-midis240","title":"V-TUF MIDI SYNCRO 21L H-Class Dust Extraction Vacuum Cleaner - 1400W with PTO \u0026 Auto Filter Shaker - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eAn H-Class vacuum — ideal for mould, asbestos and hazardous dust environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIDI SYNCRO 21L H-Class 240V Industrial Dust Extraction Vacuum Cleaner (MIDIS240)\u003c\/strong\u003e is a 21-litre H-Class dust extractor with Power Take-Off (PTO) and automatic filter shaker, synchronising with your power tool for hands-free on-tool extraction on 240V mains supply. For 110V see MIDIS110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction trades, refurbishment contractors, and site operatives requiring H-Class on-tool extraction on 240V mains supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA — 99.995% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor power: 1400W, 240V\u003c\/li\u003e\n\u003cli\u003eTank capacity: 21 litres\u003c\/li\u003e\n\u003cli\u003ePTO: Auto-synchronises with connected power tool\u003c\/li\u003e\n\u003cli\u003eAuto filter shaker: Maintains suction during use\u003c\/li\u003e\n\u003cli\u003eHose: 5m × 32mm Hi-Viz yellow\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMIDIS240 machine\u003c\/li\u003e\n\u003cli\u003e5m × 32mm Hi-Viz hose\u003c\/li\u003e\n\u003cli\u003eStainless steel wand set, 420mm floor head\u003c\/li\u003e\n\u003cli\u003eUniversal power tool adaptor\u003c\/li\u003e\n\u003cli\u003eH-Class cartridge filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag changes. Dry recovery only.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class extraction mandatory for all vacuum work near asbestos-containing materials. M-Class is not permitted for asbestos dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — H-Class required for hazardous dust including silica, asbestos, mould spores and lead paint particles. The 14-month LEV examination requirement applies.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eConstruction Design and Management Regulations 2015 (CDM 2015)\u003c\/a\u003e — H-Class is required wherever the COSHH assessment identifies a hazardous dust classification.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e — RCS WEL 0.1 mg\/m³. H-Class on-tool extraction is the primary engineering control for silica-generating tasks on construction sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/concrete-cutting-grinding-live-sites-dust-control\"\u003eConcrete cutting and grinding on live sites: dust control and COSHH compliance →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires for contractors in pre-2000 buildings →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799381524820,"sku":"MIDIS240","price":1069.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIDIS240_1S_cc90073f-8e23-475e-9521-3083b5dfcf3f.jpg?v=1779300988"},{"product_id":"vtuf-grindex20hrb240-240v-m-class-industrial-dust-extractor","title":"V-TUF GRINDEX20HRB-240 240V M CLASS INDUSTRIAL DUST EXTRACTOR","description":"\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX20HRB 240V M-Class Industrial Dust Extractor (GRINDEX20HRB-240)\u003c\/strong\u003e is a compact M-Class industrial dust extractor designed specifically for use with angle grinders and surface grinders — with auto-start synchronisation and robust construction for intensive grinding applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e floor grinding contractors, concrete restoration teams, and tradespeople using angle grinders or surface grinders on construction sites where M-Class dust extraction is legally required for silica and concrete dust.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFiltration: M-Class HEPA — compliant for silica, concrete, and masonry dust\u003c\/li\u003e\n  \u003cli\u003eMotor power: 1200W, 240V\u003c\/li\u003e\n  \u003cli\u003eAutomatic start — synchronises with connected grinder\u003c\/li\u003e\n  \u003cli\u003eCompact, robust construction for site use\u003c\/li\u003e\n  \u003cli\u003eHose: high-performance anti-crush vacuum hose\u003c\/li\u003e\n  \u003cli\u003ePower cable: 5m\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eGRINDEX20HRB-240 machine\u003c\/li\u003e\n  \u003cli\u003eVacuum hose\u003c\/li\u003e\n  \u003cli\u003eM-Class cartridge filter\u003c\/li\u003e\n  \u003cli\u003eUniversal grinder adaptor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class dust extraction is the minimum legal requirement for silica dust under CDM 2015. For asbestos remediation H-Class is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e Call our Lincoln service team on 01522 787978.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799383163220,"sku":"GRINDEX20HRB-240","price":1704.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX20HRB_1.jpg?v=1778844184"},{"product_id":"vtuf-grindex20hrb110-110v-m-class-industrial-dust-extractor","title":"V-TUF GRINDEX20HRB-110 110V M CLASS INDUSTRIAL DUST EXTRACTOR","description":"\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX20HRB 110V M-Class Industrial Dust Extractor (GRINDEX20HRB-110)\u003c\/strong\u003e is a compact M-Class industrial dust extractor designed specifically for use with angle grinders and surface grinders — with auto-start synchronisation and robust construction for intensive grinding applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e floor grinding contractors, concrete restoration teams, and tradespeople using angle grinders or surface grinders on construction sites where M-Class dust extraction is legally required for silica and concrete dust.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFiltration: M-Class HEPA — compliant for silica, concrete, and masonry dust\u003c\/li\u003e\n  \u003cli\u003eMotor power: 1200W, 110V\u003c\/li\u003e\n  \u003cli\u003eAutomatic start — synchronises with connected grinder\u003c\/li\u003e\n  \u003cli\u003eCompact, robust construction for site use\u003c\/li\u003e\n  \u003cli\u003eHose: high-performance anti-crush vacuum hose\u003c\/li\u003e\n  \u003cli\u003ePower cable: 5m\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eGRINDEX20HRB-110 machine\u003c\/li\u003e\n  \u003cli\u003eVacuum hose\u003c\/li\u003e\n  \u003cli\u003eM-Class cartridge filter\u003c\/li\u003e\n  \u003cli\u003eUniversal grinder adaptor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class dust extraction is the minimum legal requirement for silica dust under CDM 2015. For asbestos remediation H-Class is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e Call our Lincoln service team on 01522 787978.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799383785812,"sku":"GRINDEX20HRB-110","price":1704.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX20HRB_1.jpg?v=1778844184"},{"product_id":"vtuf-ruckvac-hsv-240v-industrial-backpack-vacuum-cleaner-with-lung-safe-hepa-h14-filtration","title":"V-TUF RUCKVAC HSV 240v Industrial Backpack Vacuum Cleaner - with Lung Safe Hepa H14 Filtration","description":"\u003cp\u003e\u003cstrong\u003eAn H-Class backpack vacuum — ideal for confined space and hazardous dust cleaning.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF RUCKVAC HSV 240V Industrial Backpack Vacuum Cleaner — Lung-Safe HEPA Filtration (RUCKVACHSV-240)\u003c\/strong\u003e is a corded H-Class rated backpack industrial vacuum delivering high-performance dust extraction in confined spaces where a wheeled machine can't go.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, refurbishment trades, and operatives working in tight, awkward, or elevated spaces — lofts, plant rooms, scaffolding, staircases — who need H-Class compliant dust extraction with hands-free mobility.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H13 HEPA — 99.995% extraction efficiency\u003c\/li\u003e\n\u003cli\u003eMotor power: 1400W bypass motor, 240V\u003c\/li\u003e\n\u003cli\u003eTank capacity: 21 litres (bag capacity 16L)\u003c\/li\u003e\n\u003cli\u003eAir velocity: 26 m\/sec — visual airflow monitor alerts below 20 m\/sec\u003c\/li\u003e\n\u003cli\u003eWeight: 7 kg including all accessories\u003c\/li\u003e\n\u003cli\u003ePower cable: 5m\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRUCKVACHSV-240 machine with backpack harness\u003c\/li\u003e\n\u003cli\u003e32mm × 2m yellow anti-crush hose\u003c\/li\u003e\n\u003cli\u003eChrome steel wand set\u003c\/li\u003e\n\u003cli\u003eH13 HEPA essential filter\u003c\/li\u003e\n\u003cli\u003e400mm hard floor sweeper head\u003c\/li\u003e\n\u003cli\u003eCarpet floor head, crevice tool, power tool adaptor\u003c\/li\u003e\n\u003cli\u003ePack of 10 dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag changes. Dry recovery only. For 110V see RUCKVACHSV-110.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — The RUCKVAC HSV is specified for ICRA Type C and D works inside NHS hospitals. H-Class extraction is mandatory in medium and high patient-risk zones.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class extraction is mandatory for all vacuum work near asbestos-containing materials. The backpack format is ideal for awkward pre-2000 building stock.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould spores are biological agents under COSHH. H-Class extraction is required for mould remediation in social housing.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e — Mould remediation inside occupied social housing must use H-Class extraction under the Social Housing (Regulation) Act 2023.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/awaabs-law-social-housing-maintenance-contractors\"\u003eAwaab's Law: what it means for social housing maintenance contractors →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/damp-mould-void-properties-social-housing\"\u003eDamp and mould in void properties: H-Class extraction and the correct remediation standard →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/communal-area-cleaning-high-rise-social-housing\"\u003eCommunal area cleaning in high-rise social housing: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799383982420,"sku":"RUCKVACHSV-240","price":320.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/RUCKVACHSV-240_1.jpg?v=1778844050"},{"product_id":"vtuf-mini-hsv-x2-mclass-dust-extraction-vacuum-cleaner-110v","title":"V-TUF MINI HSV X2 M-Class Dust Extraction Vacuum Cleaner - 110V","description":"\u003cp\u003e\u003cstrong\u003eAn M-Class dust extractor — ideal for on-tool extraction during cutting and grinding.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MINI HSV X2 M-Class Dust Extraction Vacuum Cleaner 110V (MINIHSV-X2-110)\u003c\/strong\u003e is a compact M-Class H13 HEPA dust extraction vacuum on 110V site-safe supply, capturing 99.9% of hazardous dust particles. For 240V version see MINIHSV-X2-240.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Tradespeople, construction workers, and workshop operators on 110V site supply requiring compact M-Class dust extraction compliance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% extraction efficiency\u003c\/li\u003e\n\u003cli\u003eVoltage: 110V site-safe\u003c\/li\u003e\n\u003cli\u003ePower Take-Off (PTO): Synchronised with power tool\u003c\/li\u003e\n\u003cli\u003eCompact design for easy site transport\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMINI HSV X2 110V machine\u003c\/li\u003e\n\u003cli\u003eHose, wand, and floor tool\u003c\/li\u003e\n\u003cli\u003eM-Class H13 HEPA filter\u003c\/li\u003e\n\u003cli\u003ePack of dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only — not suitable for H-Class hazardous materials including asbestos. For H-Class see MIDIH110 or MIDIHSV110.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class extraction is the minimum legal standard for construction dust including wood dust, plaster dust and general masonry dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eConstruction Design and Management Regulations 2015 (CDM 2015)\u003c\/a\u003e — M-Class is the minimum extraction class required for most dust-generating tasks on construction sites.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/electricity-at-work-regulations\"\u003eElectricity at Work Regulations 1989\u003c\/a\u003e — 110V CTE is the standard site-safe electrical supply for UK construction sites.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e — M-Class extraction with water suppression is the specified control for most silica-generating tasks.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/puwer\"\u003ePUWER 1998\u003c\/a\u003e — Work equipment including dust extractors must be suitable for purpose, maintained in safe condition, and operated by trained personnel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/concrete-cutting-grinding-live-sites-dust-control\"\u003eConcrete cutting and grinding on live sites: dust control and COSHH compliance →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799386767700,"sku":"MINIX2110","price":187.61,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MINIX2110_1.jpg?v=1778843615"},{"product_id":"vtuf-mini-hsv-x2-mclass-dust-extraction-vacuum-cleaner-240v","title":"V-TUF MINI HSV X2 - M-Class Dust Extraction Vacuum Cleaner - 240V","description":"\u003cp\u003e\u003cstrong\u003eAn M-Class dust extractor — ideal for on-tool extraction during cutting and grinding.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MINI HSV X2 M-Class Dust Extraction Vacuum Cleaner 240V (MINIHSV-X2-240)\u003c\/strong\u003e is a compact M-Class H13 HEPA dust extraction vacuum on 240V mains supply, capturing 99.9% of hazardous dust particles. For 110V version see MINIX2110.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Tradespeople, construction workers, and workshop operators on 240V mains requiring compact M-Class dust extraction compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiltration: M-Class H13 HEPA — 99.9% extraction efficiency\u003c\/li\u003e\n\u003cli\u003eVoltage: 240V mains\u003c\/li\u003e\n\u003cli\u003ePower Take-Off (PTO): Synchronised with power tool\u003c\/li\u003e\n\u003cli\u003eCompact design for easy transport\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMINI HSV X2 240V machine\u003c\/li\u003e\n\u003cli\u003eHose, wand, and floor tool\u003c\/li\u003e\n\u003cli\u003eM-Class H13 HEPA filter\u003c\/li\u003e\n\u003cli\u003ePack of dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e M-Class only — not suitable for H-Class hazardous materials including asbestos. For H-Class see MIDIH240 or MIDIHSV240.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — M-Class extraction is the minimum legal standard for construction dust.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eConstruction Design and Management Regulations 2015 (CDM 2015)\u003c\/a\u003e — M-Class is the minimum extraction class required for most dust-generating tasks on construction sites.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e — M-Class extraction with water suppression is the specified control for most silica-generating tasks on site.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/puwer\"\u003ePUWER 1998\u003c\/a\u003e — Work equipment including dust extractors must be suitable for purpose, maintained in safe condition, and operated by trained personnel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/concrete-cutting-grinding-live-sites-dust-control\"\u003eConcrete cutting and grinding on live sites: dust control and COSHH compliance →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799386931540,"sku":"MINIX2240","price":187.61,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MINIX2240_1.jpg?v=1778843556"},{"product_id":"vtuf-grindex1100lps-25l-110v","title":"V-TUF GRINDEX1100LPS H-Class Industrial Dust Extractor - 25L, 1150W - 110V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection for the finest, most hazardous dust on site.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1100LPS-110\u003c\/strong\u003e is a compact H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built to keep operators safe when vacuuming very fine, hazardous dust.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, tradespeople and industrial operators who need certified H-Class extraction when grinding, drilling, cutting or demolishing materials that release fine, hazardous dust.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 1150W | Voltage: 110V, 50\/60Hz | Amperage: 10A\u003c\/li\u003e\n\u003cli\u003eAirflow: 200 m³\/h | Max vacuum (depression): 250 mBar\u003c\/li\u003e\n\u003cli\u003eSuction inlet: Ø50mm tangential\u003c\/li\u003e\n\u003cli\u003eCapacity: 25L, Longopac® bagged collection system\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 48 × 44 × 104 cm | Weight: 25 kg\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: Ø330mm\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 10,000cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic reverse-flow system, differential-pressure triggered\u003c\/li\u003e\n\u003cli\u003eOptional secondary filter: HEPA H14 (99.995% @ 0.12μm), 11,200cm² surface\u003c\/li\u003e\n\u003cli\u003ePower tool socket: max 2200W, tool-start (PTO) system\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1100LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1100LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1100lps-troubleshooting\"\u003eGRINDEX1100LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1100lps-spare-parts\"\u003eGRINDEX1100LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384318767444,"sku":"GRINDEX1100LPS-110","price":2139.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1100LPS-110_1.jpg?v=1788426387"},{"product_id":"vtuf-grindex1100lps-25l-240v","title":"V-TUF GRINDEX1100LPS H-Class Industrial Dust Extractor - 25L, 1100W - 240V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection for the finest, most hazardous dust on site.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1100LPS-240\u003c\/strong\u003e is a compact H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built to keep operators safe when vacuuming very fine, hazardous dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, tradespeople and industrial operators who need certified H-Class extraction when grinding, drilling, cutting or demolishing materials that release fine, hazardous dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 1100W | Voltage: 240V, 50\/60Hz | Amperage: 4.8A\u003c\/li\u003e\n\u003cli\u003eAirflow: 200 m³\/h | Max vacuum (depression): 250 mBar\u003c\/li\u003e\n\u003cli\u003eSuction inlet: Ø50mm tangential\u003c\/li\u003e\n\u003cli\u003eCapacity: 25L, Longopac® bagged collection system\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 48 × 44 × 104 cm | Weight: 25 kg\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: Ø330mm\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 10,000cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic reverse-flow system, differential-pressure triggered\u003c\/li\u003e\n\u003cli\u003eOptional secondary filter: HEPA H14 (99.995% @ 0.12μm), 11,200cm² surface\u003c\/li\u003e\n\u003cli\u003ePower tool socket: max 2200W, tool-start (PTO) system\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1100LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1100LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1100lps-troubleshooting\"\u003eGRINDEX1100LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1100lps-spare-parts\"\u003eGRINDEX1100LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384337903956,"sku":"GRINDEX1100LPS-240","price":2139.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1100LPS-110_1.jpg?v=1788426387"},{"product_id":"vtuf-grindex1200lps-2000w-110v","title":"V-TUF GRINDEX1200LPS H-Class Industrial Dust Extractor - 2000W - 110V","description":"\u003cp\u003e\u003cstrong\u003ePowerful, compact H-Class extraction for grinders, scarifiers and surface-prep tools — where fine, hazardous dust can't be allowed back into the air.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1200LPS (GRINDEX1200LPS-110)\u003c\/strong\u003e is a twin by-pass motor industrial dust extractor built for continuous, high-volume collection of hazardous fine dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e contractors and facilities teams running grinders, scarifiers, floor prep and other dust-generating tools where hazardous or fine dust must be captured at source.\u003c\/p\u003e\u003ch4\u003eKey Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMotor: 2 x by-pass motors\u003c\/li\u003e\n\u003cli\u003ePower: 2000W | Voltage: 110V - 60Hz | Max depression: 200mBar\u003c\/li\u003e\n\u003cli\u003eAirflow: 340 m³\/h\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 70 × 54 × 135 cm | Weight: 61 kg\u003c\/li\u003e\n\u003cli\u003eTank diameter: 370mm | Suction inlet: Ø50mm\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Fully automatic (reverse air-flow)\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 0.8m² filtering surface\u003c\/li\u003e\n\u003cli\u003eCertified class: H (hazardous dust)\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® continuous bagging, 22m\u003c\/li\u003e\n\u003cli\u003eProtection rating: IP54\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eImportant\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids — dry\/solid material collection only.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage on the rating plate (110V - 60Hz) before use.\u003c\/li\u003e\n\u003cli\u003eUse only genuine V-TUF filters and spare parts — non-approved parts can compromise safety and will void the warranty.\u003c\/li\u003e\n\u003cli\u003eNot for use in the presence of explosive or toxic gases, or for vacuuming explosive, incendiary, or flammable dusts and liquids.\u003c\/li\u003e\n\u003cli\u003eCheck filter condition and correct fitting before every use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003ch4\u003eWhere This Machine Is Used\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial Housing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLegislation That Applies\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine used to control hazardous fine dust, this extractor supports compliance with the Control of Substances Hazardous to Health Regulations, which require employers to assess and control exposure to hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, H-Class dust extractors like this one form part of the dust-control measures expected under the Construction (Design and Management) Regulations 2015.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction supports staying within the workplace exposure limits (WELs) set out in HSE guidance document EH40 for substances such as respirable crystalline silica.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e This machine's H-Class certification means it is suitable for use on tasks involving asbestos-containing materials, in line with CAR 2012 requirements — always confirm safe working procedures for any known or suspected asbestos before starting work.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e As with all machines used in commercial or industrial settings, this extractor should be maintained, inspected and operated in line with the Provision and Use of Work Equipment Regulations 1998.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where this machine is used on construction or refurbishment work inside healthcare settings, H-Class extraction supports compliance with Infection Control Risk Assessment requirements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation or associated dust control in social housing, H-Class extractors fall within the scope of Awaab's Law obligations on landlords.\u003c\/p\u003e\u003ch4\u003eFurther Reading\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSupport\u003c\/h4\u003e\u003cp\u003eNeed help with this machine? Visit our \u003ca href=\"\/pages\/grindex1200lps-troubleshooting\"\u003etroubleshooting guide\u003c\/a\u003e or \u003ca href=\"\/pages\/grindex1200lps-spare-parts\"\u003espare parts page\u003c\/a\u003e, or call us on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384716079444,"sku":"GRINDEX1200LPS-110","price":3637.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1200LP-110_1.jpg?v=1788426386"},{"product_id":"vtuf-grindex1200lps-2200w-240v","title":"V-TUF GRINDEX1200LPS H-Class Industrial Dust Extractor - 2200W - 240V","description":"\u003cp\u003e\u003cstrong\u003ePowerful, compact H-Class extraction for grinders, scarifiers and surface-prep tools — where fine, hazardous dust can't be allowed back into the air.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1200LPS (GRINDEX1200LPS-240)\u003c\/strong\u003e is a twin by-pass motor industrial dust extractor built for continuous, high-volume collection of hazardous fine dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e contractors and facilities teams running grinders, scarifiers, floor prep and other dust-generating tools where hazardous or fine dust must be captured at source.\u003c\/p\u003e\u003ch4\u003eKey Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMotor: 2 x by-pass motors\u003c\/li\u003e\n\u003cli\u003ePower: 2200W | Voltage: 230V - 50Hz | Max depression: 230mBar\u003c\/li\u003e\n\u003cli\u003eAirflow: 340 m³\/h\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 70 × 54 × 135 cm | Weight: 61 kg\u003c\/li\u003e\n\u003cli\u003eTank diameter: 370mm | Suction inlet: Ø50mm\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Fully automatic (reverse air-flow)\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 0.8m² filtering surface\u003c\/li\u003e\n\u003cli\u003eCertified class: H (hazardous dust)\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® continuous bagging, 22m\u003c\/li\u003e\n\u003cli\u003eProtection rating: IP54\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eImportant\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids — dry\/solid material collection only.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage on the rating plate (230V - 50Hz) before use.\u003c\/li\u003e\n\u003cli\u003eUse only genuine V-TUF filters and spare parts — non-approved parts can compromise safety and will void the warranty.\u003c\/li\u003e\n\u003cli\u003eNot for use in the presence of explosive or toxic gases, or for vacuuming explosive, incendiary, or flammable dusts and liquids.\u003c\/li\u003e\n\u003cli\u003eCheck filter condition and correct fitting before every use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003ch4\u003eWhere This Machine Is Used\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial Housing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLegislation That Applies\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine used to control hazardous fine dust, this extractor supports compliance with the Control of Substances Hazardous to Health Regulations, which require employers to assess and control exposure to hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, H-Class dust extractors like this one form part of the dust-control measures expected under the Construction (Design and Management) Regulations 2015.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction supports staying within the workplace exposure limits (WELs) set out in HSE guidance document EH40 for substances such as respirable crystalline silica.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e This machine's H-Class certification means it is suitable for use on tasks involving asbestos-containing materials, in line with CAR 2012 requirements — always confirm safe working procedures for any known or suspected asbestos before starting work.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e As with all machines used in commercial or industrial settings, this extractor should be maintained, inspected and operated in line with the Provision and Use of Work Equipment Regulations 1998.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where this machine is used on construction or refurbishment work inside healthcare settings, H-Class extraction supports compliance with Infection Control Risk Assessment requirements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation or associated dust control in social housing, H-Class extractors fall within the scope of Awaab's Law obligations on landlords.\u003c\/p\u003e\u003ch4\u003eFurther Reading\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSupport\u003c\/h4\u003e\u003cp\u003eNeed help with this machine? Visit our \u003ca href=\"\/pages\/grindex1200lps-troubleshooting\"\u003etroubleshooting guide\u003c\/a\u003e or \u003ca href=\"\/pages\/grindex1200lps-spare-parts\"\u003espare parts page\u003c\/a\u003e, or call us on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384721617236,"sku":"GRINDEX1200LPS-240","price":3637.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1200LP-110_1.jpg?v=1788426386"},{"product_id":"vtuf-grindex1300lps-3300w-110v","title":"V-TUF GRINDEX1300LPS H-Class Industrial Dust Extractor - 3300W, 450m³\/h - 110V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection built for the toughest industrial dust extraction jobs.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1300LPS-110\u003c\/strong\u003e is a high-capacity, three-motor H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built for continuous operation with surface preparation machinery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors and industrial operators running grinders, scarifiers, sanders and shot blasters who need certified H-Class extraction for very fine, hazardous dust over extended shifts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 3300W total | Voltage: 110V, 60Hz\u003c\/li\u003e\n\u003cli\u003eMotor: 3× by-pass motors\u003c\/li\u003e\n\u003cli\u003eAirflow: 450 m³\/h | Max vacuum (depression): 200 mBar\u003c\/li\u003e\n\u003cli\u003eTangential suction inlet\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE, 3× cartridge, 20,500cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic, continuous-suction reverse-flow system\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® 22m continuous bag, optional 100L tank\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: 460mm\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1300LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1300LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1300lps-troubleshooting\"\u003eGRINDEX1300LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1300lps-spare-parts\"\u003eGRINDEX1300LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56385125810516,"sku":"GRINDEX1300LPS-110","price":5389.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1300LPS_1.jpg?v=1783504545"},{"product_id":"vtuf-grindex1300lps-3300w-240v","title":"V-TUF GRINDEX1300LPS H-Class Industrial Dust Extractor - 3300W, 510m³\/h - 240V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection built for the toughest industrial dust extraction jobs.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1300LPS-240\u003c\/strong\u003e is a high-capacity, three-motor H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built for continuous operation with surface preparation machinery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors and industrial operators running grinders, scarifiers, sanders and shot blasters who need certified H-Class extraction for very fine, hazardous dust over extended shifts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 3300W total | Voltage: 230V, 50Hz\u003c\/li\u003e\n\u003cli\u003eMotor: 3× by-pass motors\u003c\/li\u003e\n\u003cli\u003eAirflow: 510 m³\/h | Max vacuum (depression): 230 mBar\u003c\/li\u003e\n\u003cli\u003eTangential suction inlet\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE, 3× cartridge, 20,500cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic, continuous-suction reverse-flow system\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® 22m continuous bag, optional 100L tank\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: 460mm\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1300LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1300LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1300lps-troubleshooting\"\u003eGRINDEX1300LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1300lps-spare-parts\"\u003eGRINDEX1300LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56385132429652,"sku":"GRINDEX1300LPS-240","price":5389.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1300LPS_1.jpg?v=1783504545"},{"product_id":"grindex1100lp-110","title":"V-TUF GRINDEX1100LP M-Class Industrial Dust Extractor - 20L, 1150W - 110V","description":"\u003cp\u003e\u003cstrong\u003eContinuous, compact fine-dust extraction built for demanding industrial and construction environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1100LP\u003c\/strong\u003e (SKU: GRINDEX1100LP-110) is a compact M-Class industrial dust extractor with a 20L capacity, a HEPA+PTFE cartridge filter, and manual reverse-flow filter cleaning for continuous operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, facilities teams and manufacturers who need reliable, compact fine-dust extraction for grinding, cutting, sanding and general construction or workshop dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eM-Class | 20L capacity | 1150W motor | 110V\u003c\/li\u003e\n\u003cli\u003eAirflow: 200 m³\/h | Max depression: 250 mBar | Suction inlet: Ø50mm tangential\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 10,000cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Manual reverse-flow (pulse)\u003c\/li\u003e\n\u003cli\u003eOptional secondary filter: HEPA H14, 99.995% @ 0.12μm, 11,200cm²\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® bag | Filter chamber: Ø330mm\u003c\/li\u003e\n\u003cli\u003eWeight: 25kg | Dimensions: 480 x 440 x 1040mm (L x W x H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Not suitable for vacuuming liquids. On 3-phase 110V models, confirm the motor rotates clockwise before use; if rotation is reversed, disconnect from the power source and swap one phase cable in the plug. Not for use in explosive atmospheres or where hazardous gases may be present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e applies to all dust-generating machines; operators must assess and control exposure to hazardous substances including fine dust.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e applies to this machine when used on construction sites, setting out duties for managing health and safety risks including dust control.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e set the maximum permitted exposure to airborne substances such as silica dust; M-Class extraction is the minimum standard for many of these tasks.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/puwer\"\u003ePUWER 1998\u003c\/a\u003e applies to this machine when used in commercial or industrial settings, requiring it to be suitable, maintained and used safely.\u003c\/p\u003e\n\u003cp\u003eIf used for mould remediation in social housing, \u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e may also apply — this M-Class model is suitable for that use case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther Reading:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNeed help? See our \u003ca href=\"\/pages\/grindex1100lp-troubleshooting\"\u003eGRINDEX1100LP troubleshooting guide\u003c\/a\u003e or find \u003ca href=\"\/pages\/grindex1100lp-spare-parts\"\u003egenuine GRINDEX1100LP spare parts\u003c\/a\u003e. Call us on \u003ca href=\"tel:+441522787978\"\u003e+44 (0)1522 787978\u003c\/a\u003e or email \u003ca href=\"mailto:enquiries@v-tuf.com\"\u003eenquiries@v-tuf.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56385202913620,"sku":"GRINDEX1100LP-110","price":1711.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1100LP-110_1.jpg?v=1788426387"},{"product_id":"grindex1100lp-240","title":"V-TUF GRINDEX1100LP M-Class Industrial Dust Extractor - 20L, 1100W - 240V","description":"\u003cp\u003e\u003cstrong\u003eContinuous, compact fine-dust extraction built for demanding industrial and construction environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1100LP\u003c\/strong\u003e (SKU: GRINDEX1100LP-240) is a compact M-Class industrial dust extractor with a 20L capacity, a HEPA+PTFE cartridge filter, and manual reverse-flow filter cleaning for continuous operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, facilities teams and manufacturers who need reliable, compact fine-dust extraction for grinding, cutting, sanding and general construction or workshop dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eM-Class | 20L capacity | 1100W motor | 240V\u003c\/li\u003e\n\u003cli\u003eAirflow: 200 m³\/h | Max depression: 250 mBar | Suction inlet: Ø50mm tangential\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 10,000cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Manual reverse-flow (pulse)\u003c\/li\u003e\n\u003cli\u003eOptional secondary filter: HEPA H14, 99.995% @ 0.12μm, 11,200cm²\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® bag | Filter chamber: Ø330mm\u003c\/li\u003e\n\u003cli\u003eWeight: 25kg | Dimensions: 480 x 440 x 1040mm (L x W x H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Not suitable for vacuuming liquids. Not for use in explosive atmospheres or where hazardous gases may be present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e applies to all dust-generating machines; operators must assess and control exposure to hazardous substances including fine dust.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e applies to this machine when used on construction sites, setting out duties for managing health and safety risks including dust control.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e set the maximum permitted exposure to airborne substances such as silica dust; M-Class extraction is the minimum standard for many of these tasks.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/puwer\"\u003ePUWER 1998\u003c\/a\u003e applies to this machine when used in commercial or industrial settings, requiring it to be suitable, maintained and used safely.\u003c\/p\u003e\n\u003cp\u003eIf used for mould remediation in social housing, \u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e may also apply — this M-Class model is suitable for that use case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther Reading:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNeed help? See our \u003ca href=\"\/pages\/grindex1100lp-troubleshooting\"\u003eGRINDEX1100LP troubleshooting guide\u003c\/a\u003e or find \u003ca href=\"\/pages\/grindex1100lp-spare-parts\"\u003egenuine GRINDEX1100LP spare parts\u003c\/a\u003e. Call us on \u003ca href=\"tel:+441522787978\"\u003e+44 (0)1522 787978\u003c\/a\u003e or email \u003ca href=\"mailto:enquiries@v-tuf.com\"\u003eenquiries@v-tuf.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56385206452564,"sku":"GRINDEX1100LP-240","price":1711.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1100LP-110_1.jpg?v=1788426387"},{"product_id":"v-tuf-aeromax800-air-scrubber-110v","title":"V-TUF AEROMAX800 Air Scrubber - 700CFM, H13 HEPA - 110V","description":"\u003cp\u003e\u003cstrong\u003eA high-performance portable air scrubber that captures airborne dust, mould spores and fine particulates to protect indoor air quality on restoration and construction sites.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX800\u003c\/strong\u003e (SKU: AEROMAX800-110) is a professional air filtration system for mould remediation, water-damage restoration and dust control, drawing air through multi-stage filtration at up to 700 CFM.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Restoration and construction professionals who need continuous, high-volume air filtration to control airborne contaminants and improve indoor air quality.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximum airflow: 700 CFM (19.8 m³\/min)\u003c\/li\u003e\n\u003cli\u003eRecommended for spaces of 100–170 m³\u003c\/li\u003e\n\u003cli\u003eFiltration: multi-stage — G4 pre-filter + H13 HEPA filter (99.95%)\u003c\/li\u003e\n\u003cli\u003eVariable stepless speed control\u003c\/li\u003e\n\u003cli\u003eDaisy-chain capable — two external sockets to run multiple units from one supply\u003c\/li\u003e\n\u003cli\u003eMotor speed: 2,450 RPM\u003c\/li\u003e\n\u003cli\u003eRugged rotomoulded housing\u003c\/li\u003e\n\u003cli\u003eDimensions: 61 × 35 × 56 cm | Weight: 15.0 kg\u003c\/li\u003e\n\u003cli\u003ePower supply: 110V \/ 50Hz (transformer supply)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e Activated carbon filter or HEPA + carbon combination for odour and VOC removal; optional UV-C module for enhanced biological sterilisation (sold separately).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1× V-TUF AEROMAX800 air scrubber with G4 pre-filter and H13 HEPA filter fitted\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Tool-free filter changes via heavy-duty hasps. Requires a 110V transformer supply. Position the unit for effective air circulation across the work area and replace filters in line with dust loading.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; site work\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing — damp \u0026amp; mould remediation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; infection control\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e:\u003c\/strong\u003e Employers must control exposure to hazardous airborne substances. High-volume HEPA air filtration helps reduce airborne dust and contaminant concentrations at the work area.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e:\u003c\/strong\u003e On construction, refurbishment and demolition projects, dust and air-quality controls form part of managing site health risks under the Construction (Design and Management) Regulations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e:\u003c\/strong\u003e Air filtration supports keeping airborne dust below the workplace exposure limits set out in EH40, alongside extraction at source.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012\u003c\/a\u003e:\u003c\/strong\u003e Where used to filter air within an asbestos enclosure, a HEPA unit can form part of the controls under CAR 2012 — subject to a suitable risk assessment and, where applicable, licensed working.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e:\u003c\/strong\u003e For social-housing damp and mould remediation, air scrubbers support the timely, effective remediation expected under Awaab's Law.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/icra\"\u003eICRA\u003c\/a\u003e:\u003c\/strong\u003e In healthcare settings, HEPA air filtration supports Infection Control Risk Assessment requirements during construction or refurbishment near patient areas.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/understanding-asbestos\"\u003eUnderstanding asbestos: health risks, causes and solutions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/combat-risks-hazardous-construction-dust\"\u003eCombating the risks of hazardous construction dust\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56709108171092,"sku":"Aeromax800-110","price":839.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/AEROMAX800-2-DRAFT_b7cef198-f0e8-4a98-94be-3bf9a7e99920.jpg?v=1786103704"},{"product_id":"v-tuf-aeromax800-air-scrubber-240v","title":"V-TUF AEROMAX800 Air Scrubber - 700CFM, H14 HEPA - 240V","description":"\u003cp\u003e\u003cstrong\u003eA high-performance portable air scrubber that captures airborne dust, mould spores and fine particulates to protect indoor air quality on restoration and construction sites.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX800\u003c\/strong\u003e (SKU: AEROMAX800-240) is a professional air filtration system for mould remediation, water-damage restoration and dust control, drawing air through multi-stage filtration at up to 700 CFM.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Restoration and construction professionals who need continuous, high-volume air filtration to control airborne contaminants and improve indoor air quality.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximum airflow: 700 CFM (19.8 m³\/min)\u003c\/li\u003e\n\u003cli\u003eRecommended for spaces of 100–170 m³\u003c\/li\u003e\n\u003cli\u003eFiltration: multi-stage — G4 pre-filter + H14 HEPA filter (99.995%)\u003c\/li\u003e\n\u003cli\u003eVariable stepless speed control\u003c\/li\u003e\n\u003cli\u003eDaisy-chain capable — two external sockets to run multiple units from one supply\u003c\/li\u003e\n\u003cli\u003eMotor speed: 2,450 RPM\u003c\/li\u003e\n\u003cli\u003eRugged rotomoulded housing\u003c\/li\u003e\n\u003cli\u003eDimensions: 61 × 35 × 56 cm | Weight: 15.0 kg\u003c\/li\u003e\n\u003cli\u003ePower supply: 240V \/ 50Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e Activated carbon filter or HEPA + carbon combination for odour and VOC removal; optional UV-C module for enhanced biological sterilisation (sold separately).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1× V-TUF AEROMAX800 air scrubber with G4 pre-filter and H14 HEPA filter fitted\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Tool-free filter changes via heavy-duty hasps. Position the unit for effective air circulation across the work area and replace filters in line with dust loading.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; site work\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing — damp \u0026amp; mould remediation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; infection control\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e:\u003c\/strong\u003e Employers must control exposure to hazardous airborne substances. High-volume HEPA air filtration helps reduce airborne dust and contaminant concentrations at the work area.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e:\u003c\/strong\u003e On construction, refurbishment and demolition projects, dust and air-quality controls form part of managing site health risks under the Construction (Design and Management) Regulations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e:\u003c\/strong\u003e Air filtration supports keeping airborne dust below the workplace exposure limits set out in EH40, alongside extraction at source.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012\u003c\/a\u003e:\u003c\/strong\u003e Where used to filter air within an asbestos enclosure, an H14 HEPA unit can form part of the controls under CAR 2012 — subject to a suitable risk assessment and, where applicable, licensed working.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e:\u003c\/strong\u003e For social-housing damp and mould remediation, air scrubbers support the timely, effective remediation expected under Awaab's Law.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/icra\"\u003eICRA\u003c\/a\u003e:\u003c\/strong\u003e In healthcare settings, HEPA air filtration supports Infection Control Risk Assessment requirements during construction or refurbishment near patient areas.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/understanding-asbestos\"\u003eUnderstanding asbestos: health risks, causes and solutions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/combat-risks-hazardous-construction-dust\"\u003eCombating the risks of hazardous construction dust\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56709108236628,"sku":"Aeromax800-240","price":839.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/AEROMAX800-2-DRAFT_b7cef198-f0e8-4a98-94be-3bf9a7e99920.jpg?v=1786103704"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/collections\/MINIX2110_3_020097c9-998d-47c0-bac5-c93ccc9794e7.jpg?v=1791797144","url":"https:\/\/www.v-tuf.co.uk\/collections\/indoor-air-quality-2027-regulation-compliant.oembed?page=2","provider":"V-TUF","version":"1.0","type":"link"}