{"title":"Awaab's Law Compliant Equipment","description":"\u003cdiv class=\"vtuf-hub-page\" style=\"max-width:960px;margin:0 auto;font-family:'Barlow',-apple-system,sans-serif;color:#1a1a1a;line-height:1.6;font-size:1.05rem\"\u003e\n\u003cp style=\"background:#000;color:#FFBA00;font-family:'Oswald',sans-serif;font-weight:700;text-transform:uppercase;letter-spacing:0.08em;font-size:1rem;padding:0.85rem 1rem;margin-bottom:1.2rem;\"\u003eAwaab's Law Compliant Equipment — The Specification for Social Housing Mould Remediation\u003c\/p\u003e\n\n\u003cp\u003eAwaab's Law (Social Housing Regulation Act 2023) sets legally enforceable timescales for investigating and remediating damp and mould in social housing. Phase 1 in force October 2025. Phase 2 from 30 November 2026. The equipment used for remediation must meet COSHH 2002 standards — mould, classified as a Hazard Group 2 biological agent, requires H-Class extraction with H14 HEPA filtration as the engineering control. This is not guidance. It is law.\u003c\/p\u003e\n\n\u003cp\u003eThe products in this collection are specified against three compliance requirements. Browse by equipment type below:\u003c\/p\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:1rem;margin:1.2rem 0\"\u003e\n\u003cdiv style=\"background:#f5f5f5;padding:1.2rem;border-left:5px solid #FFBA00\"\u003e\n\u003cstrong style=\"display:block;font-family:'Oswald',sans-serif;font-size:1.1rem;margin-bottom:0.5rem\"\u003e\u003ca href=\"\/collections\/awaabs-law-h-class-extraction\" style=\"color:#000;text-decoration:none\"\u003eH-Class Extraction →\u003c\/a\u003e\u003c\/strong\u003e\n\u003cspan style=\"font-size:0.9rem;color:#555\"\u003eGRINDEX Longopac sealed bagging, MIDI HSV and RUCKVAC HSV. The COSHH engineering control for mould remediation vacuuming. H14 HEPA at 99.995%.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f5f5f5;padding:1.2rem;border-left:5px solid #FFBA00\"\u003e\n\u003cstrong style=\"display:block;font-family:'Oswald',sans-serif;font-size:1.1rem;margin-bottom:0.5rem\"\u003e\u003ca href=\"\/collections\/awaabs-law-aeromax-air-scrubbers\" style=\"color:#000;text-decoration:none\"\u003eAEROMAX Air Scrubbers →\u003c\/a\u003e\u003c\/strong\u003e\n\u003cspan style=\"font-size:0.9rem;color:#555\"\u003eContinuous ambient air filtration during and after remediation. Controls airborne spores that on-tool extraction does not reach. 400CFM to 1200CFM.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f5f5f5;padding:1.2rem;border-left:5px solid #FFBA00\"\u003e\n\u003cstrong style=\"display:block;font-family:'Oswald',sans-serif;font-size:1.1rem;margin-bottom:0.5rem\"\u003e\u003ca href=\"\/collections\/awaabs-law-mould-removal-kits\" style=\"color:#000;text-decoration:none\"\u003eMould Removal Kits →\u003c\/a\u003e\u003c\/strong\u003e\n\u003cspan style=\"font-size:0.9rem;color:#555\"\u003eStarter, advanced and contractor packs. UKCMS Mould-Safe Code compliant treatment, extraction and PPE from one kit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-family:'Oswald',sans-serif;font-weight:700;text-transform:uppercase;font-size:1.4rem;border-left:5px solid #FFBA00;padding-left:0.85rem;margin:1.2rem 0 0.6rem\"\u003eThe three compliance requirements\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003e1. H-Class extraction — COSHH engineering control.\u003c\/strong\u003e Mould is a Hazard Group 2 biological agent. H-Class at 99.995% is the only compliant engineering control for remediation vacuuming. M-Class passes spores through its filter and exhausts them back into the room. H-Class captures and contains them.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Air scrubbing — ambient spore control.\u003c\/strong\u003e On-tool extraction captures at source. An air scrubber controls what cleaning activity disturbs and redistributes into the air. The UKCMS Mould-Safe Code specifies air scrubbing as part of the compliant process for occupied properties.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e3. Sealed waste disposal — Longopac.\u003c\/strong\u003e Filter exposure during emptying is the most common route to H-Class compliance failure. The GRINDEX range with Longopac sealed continuous bagging seals before opening — no filter exposure, no re-contamination.\u003c\/p\u003e\n\n\u003ch2 style=\"font-family:'Oswald',sans-serif;font-weight:700;text-transform:uppercase;font-size:1.4rem;border-left:5px solid #FFBA00;padding-left:0.85rem;margin:1.2rem 0 0.6rem\"\u003eAwaab's Law timescales\u003c\/h2\u003e\n\u003cul style=\"padding-left:1.4rem;margin:0 0 0.85rem\"\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003eEmergency hazards — investigation within \u003cstrong\u003e24 hours\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003eDamp and mould — investigation within \u003cstrong\u003e14 days\u003c\/strong\u003e, plan within a further \u003cstrong\u003e14 days\u003c\/strong\u003e, safety work within \u003cstrong\u003e5 working days\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003ePhase 2 — \u003cstrong\u003e30 November 2026\u003c\/strong\u003e — extended to additional HHSRS hazard categories\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003ePhase 3 — expected 2027 — full HHSRS scope\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul style=\"padding-left:1.4rem;margin:0 0 0.85rem\"\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/pages\/awaabs-law\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eAwaab's Law full guidance →\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/pages\/mould-removal-standards-ukcms-contractor-compliance\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eMould removal standards and UKCMS →\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/pages\/coshh-regulations\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eCOSHH Regulations 2002 →\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/blogs\/compliance-centre\/awaabs-law-phase-2-november-2026-contractors\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003ePhase 2 — what contractors need to know →\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:0.4rem\"\u003e\u003ca href=\"\/blogs\/compliance-centre\/awaabs-law-phase-2-november-2026-housing-associations\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003ePhase 2 — what housing associations need to know →\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eTelephone: \u003cstrong\u003e01522 787978\u003c\/strong\u003e for Awaab's Law equipment specification. \u003ca href=\"\/pages\/contact\" style=\"color:#000;font-family:'Oswald',sans-serif;font-weight:600;text-transform:uppercase;font-size:0.92rem;text-decoration:none;border-bottom:2px solid #FFBA00\"\u003eContact the V-TUF trade team →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","products":[{"product_id":"vtuf-aeromax500240-air-filtration-cleaner-turbo-fan-240v-158w","title":"V-TUF AEROMAX500-240 Air Filtration Cleaner TURBO FAN, 158W - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eA wet and dry M-Class vacuum — ideal for site clean-down and general dust control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX500-240 Air Filtration Cleaner Turbo Fan 158W 240V (AEROMAX500-240)\u003c\/strong\u003e is a 240V mains air filtration unit for construction sites and healthcare environments, continuously filtering airborne respirable dust from enclosed working areas during refurbishment and remediation works. For 110V see AEROMAX500-110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction contractors working in occupied buildings, NHS hospital refurbishment teams, and any trade requiring airborne particulate control in enclosed spaces on 240V mains supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor: 158W turbo fan, 240V mains\u003c\/li\u003e\n\u003cli\u003eFunction: Continuous air filtration of enclosed working areas\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Air filtration is a supplementary control — not a substitute for on-tool M-Class or H-Class dust extraction at source.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — ICRA Type C and D works require engineering controls to prevent airborne fungal spores from reaching patient areas. Air filtration is a specified supplementary control in high patient-risk zones alongside H-Class on-tool extraction.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Airborne respirable dust in enclosed construction environments must be controlled by engineering controls. Air filtration supplements on-tool extraction and water suppression.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Principal contractors must ensure dust control in enclosed working areas protecting both workers and building occupants.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798994927956,"sku":"AEROMAX500-240","price":1271.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/Aeromax500-240_2.jpg?v=1779288351"},{"product_id":"vtuf-aeromax500110-air-filtration-cleaner-turbo-fan-110v-158w","title":"V-TUF AEROMAX500-110 Air Filtration Cleaner TURBO FAN, 158W - 110V (Transformer Required)","description":"\u003cp\u003e\u003cstrong\u003eA wet and dry M-Class vacuum — ideal for site clean-down and general dust control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX500-110 Air Filtration Cleaner Turbo Fan 158W 110V (AEROMAX500-110)\u003c\/strong\u003e is a 110V site-safe air filtration unit for construction sites and healthcare environments, continuously filtering airborne respirable dust from enclosed working areas during refurbishment and remediation works.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction contractors working in occupied buildings, NHS hospital refurbishment teams, and any trade requiring airborne particulate control in enclosed spaces on 110V site supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor: 158W turbo fan, 110V site-safe\u003c\/li\u003e\n\u003cli\u003eFunction: Continuous air filtration of enclosed working areas\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Air filtration is a supplementary control — not a substitute for on-tool M-Class or H-Class dust extraction at source. 110V requires site transformer.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — ICRA Type C and D works require engineering controls to prevent airborne fungal spores from reaching patient areas. Air filtration is a specified supplementary control in high patient-risk zones alongside H-Class on-tool extraction.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Airborne respirable dust in enclosed construction environments must be controlled by engineering controls. Air filtration supplements on-tool extraction and water suppression.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — Principal contractors must ensure dust control in enclosed working areas protecting both workers and building occupants.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/electricity-at-work-regulations\"\u003eElectricity at Work Regulations 1989\u003c\/a\u003e — 110V CTE is the mandated supply for portable electrical equipment on UK construction sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55798994993492,"sku":"AEROMAX500-110","price":1271.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/Aeromax500-110_2.jpg?v=1779288351"},{"product_id":"vtuf-midi-hsv-21l-hclass-240v-industrial-dust-extraction-vacuum-cleaner-asbestos-health-safety-version","title":"V-TUF MIDI HSV 21L ULPA15 Industrial Dust Extraction Vacuum Cleaner - Asbestos Rated with Velocity Monitor - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eAn H-Class vacuum — ideal for mould, asbestos and hazardous dust environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIDI HSV 21L H-Class 240V Industrial Dust Extraction Vacuum Cleaner (MIDIHSV240)\u003c\/strong\u003e is a 21-litre H-Class industrial vacuum cleaner with ULPA15 filtration, capturing carcinogens, asbestos fibres, and the finest respirable dust particles with 99.9995% filtration efficiency. For 110V see MIDIHSV110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, refurbishment trades, and any environment where H-Class dust extraction is legally required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: ULPA15 — 99.9995% efficiency on respirable particles\u003c\/li\u003e\n\u003cli\u003eMotor power: 1150W turbine motor, 240V\u003c\/li\u003e\n\u003cli\u003eTank capacity: 21 litres\u003c\/li\u003e\n\u003cli\u003eAir velocity: 40m\/sec (monitored at 20m\/sec)\u003c\/li\u003e\n\u003cli\u003eHose: 5m × 32mm Hi-Viz yellow\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e5m heavy duty yellow 32mm hose\u003c\/li\u003e\n\u003cli\u003e32mm stainless steel tubes and eKgow\u003c\/li\u003e\n\u003cli\u003e420mm wide floor head, upholstery tool, round brush, crevice tool\u003c\/li\u003e\n\u003cli\u003eUniversal power tool adaptor\u003c\/li\u003e\n\u003cli\u003ePack of 15L HEPA dust bags and coned filter basket\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Dry recovery only. For asbestos work, follow BS 8520-3:2009 Code of Practice. H-Class machines require full PPE during filter and bag changes.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/motorsport-valley\"\u003eMotorsport Valley \u0026amp; composites\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class extraction is mandatory for all vacuum work involving asbestos dust across all three work categories. M-Class is not permitted for asbestos under any category.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class extraction is mandatory for Type C and D works in medium and high patient-risk zones inside NHS hospitals and healthcare facilities.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould spores, asbestos fibres, carbon fibre dust and lead paint particles are all biological or hazardous agents requiring H-Class containment under COSHH.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eConstruction Design and Management Regulations 2015 (CDM 2015)\u003c\/a\u003e — H-Class is required wherever the COSHH assessment identifies hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e — The RCS WEL of 0.1 mg\/m³ applies to all silica-generating operations. H-Class extraction is required in enclosed environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires for contractors in pre-2000 buildings →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eCAR 2012 explained: licensed, notifiable non-licensed and non-licensed asbestos work →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799285416276,"sku":"MIDIHSV240","price":962.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIDIHSV.jpg?v=1779300988"},{"product_id":"vtuf-midi-syncro-21l-hclass-240v-industrial-dust-extraction-vacuum-cleaner-with-power-take-off-midis240","title":"V-TUF MIDI SYNCRO 21L H-Class Dust Extraction Vacuum Cleaner - 1400W with PTO \u0026 Auto Filter Shaker - 240V Mains","description":"\u003cp\u003e\u003cstrong\u003eAn H-Class vacuum — ideal for mould, asbestos and hazardous dust environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MIDI SYNCRO 21L H-Class 240V Industrial Dust Extraction Vacuum Cleaner (MIDIS240)\u003c\/strong\u003e is a 21-litre H-Class dust extractor with Power Take-Off (PTO) and automatic filter shaker, synchronising with your power tool for hands-free on-tool extraction on 240V mains supply. For 110V see MIDIS110.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Construction trades, refurbishment contractors, and site operatives requiring H-Class on-tool extraction on 240V mains supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA — 99.995% efficiency\u003c\/li\u003e\n\u003cli\u003eMotor power: 1400W, 240V\u003c\/li\u003e\n\u003cli\u003eTank capacity: 21 litres\u003c\/li\u003e\n\u003cli\u003ePTO: Auto-synchronises with connected power tool\u003c\/li\u003e\n\u003cli\u003eAuto filter shaker: Maintains suction during use\u003c\/li\u003e\n\u003cli\u003eHose: 5m × 32mm Hi-Viz yellow\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMIDIS240 machine\u003c\/li\u003e\n\u003cli\u003e5m × 32mm Hi-Viz hose\u003c\/li\u003e\n\u003cli\u003eStainless steel wand set, 420mm floor head\u003c\/li\u003e\n\u003cli\u003eUniversal power tool adaptor\u003c\/li\u003e\n\u003cli\u003eH-Class cartridge filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag changes. Dry recovery only.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class extraction mandatory for all vacuum work near asbestos-containing materials. M-Class is not permitted for asbestos dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — H-Class required for hazardous dust including silica, asbestos, mould spores and lead paint particles. The 14-month LEV examination requirement applies.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eConstruction Design and Management Regulations 2015 (CDM 2015)\u003c\/a\u003e — H-Class is required wherever the COSHH assessment identifies a hazardous dust classification.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e — RCS WEL 0.1 mg\/m³. H-Class on-tool extraction is the primary engineering control for silica-generating tasks on construction sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/concrete-cutting-grinding-live-sites-dust-control\"\u003eConcrete cutting and grinding on live sites: dust control and COSHH compliance →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires for contractors in pre-2000 buildings →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":55799381524820,"sku":"MIDIS240","price":1069.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MIDIS240_1S_cc90073f-8e23-475e-9521-3083b5dfcf3f.jpg?v=1779300988"},{"product_id":"pack-1-starter-mould-remover-kit","title":"Pack 1: Starter Mould Removal Kits","description":"\u003cp\u003e\u003cstrong\u003eA complete mould remediation kit — designed for compliant cleaning under Awaab's Law and COSHH.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack 1: Starter Mould Remover Kit (MSP003)\u003c\/strong\u003e is the entry-level mould remediation kit for social housing maintenance contractors, providing the core tools needed for compliant mould removal in occupied and void social housing properties.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Social housing maintenance contractors, local authority DLO teams, and housing association operatives carrying out mould remediation in line with Awaab's Law and COSHH requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMould removal spray\u003c\/li\u003e\n\u003cli\u003ePPE for operatives\u003c\/li\u003e\n\u003cli\u003eCore remediation consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Mould remediation in social housing requires H-Class dust extraction for any disturbed mould — see the RUCKVAC HSV or MIDI HSV range. This kit provides the chemical removal layer. PPE is mandatory during application and dwell time.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere this kit is used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eRefurbishment \u0026amp; void property works\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law (Social Housing Regulation Act 2023)\u003c\/a\u003e — Social landlords must investigate damp and mould within 14 days of a report, begin emergency repairs within 24 hours where there is an immediate risk to health, and complete all mould remediation within 7 days. Written records of all remediation work must be kept.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould spores are biological agents under COSHH Schedule 3. Remediation operatives must be assessed for exposure. H-Class extraction is required where mould is disturbed. PPE is mandatory throughout.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/renting-homes-wales-act\"\u003eRenting Homes (Wales) Act 2016\u003c\/a\u003e — All rented homes in Wales must be fit for human habitation from day one. The continuous fitness standard includes freedom from damp, mould and condensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/awaabs-law-social-housing-maintenance-contractors\"\u003eAwaab's Law: what it means for social housing maintenance contractors →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/damp-mould-void-properties-social-housing\"\u003eDamp and mould in void properties: H-Class extraction and the correct remediation standard →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/communal-area-cleaning-high-rise-social-housing\"\u003eCommunal area cleaning in high-rise social housing →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/renting-homes-wales-act-maintenance-contractors\"\u003eRenting Homes (Wales) Act: what maintenance contractors need to know →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56081168892244,"sku":"MSP003","price":563.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MSP003_1.jpg?v=1781177638"},{"product_id":"pack-2-advanced-mould-remover-kit","title":"Pack 2: Advanced Mould Removal Kits","description":"\u003cp\u003e\u003cstrong\u003eA complete mould remediation kit — designed for compliant cleaning under Awaab's Law and COSHH.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack 2: Advanced Mould Remover Kit (MSP004)\u003c\/strong\u003e is the mid-tier mould remediation kit for social housing maintenance contractors, providing enhanced tools and removal products for more established mould growth in occupied and void social housing properties.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Social housing maintenance contractors, local authority DLO teams, and housing association operatives dealing with more significant mould growth requiring advanced removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced mould removal products\u003c\/li\u003e\n\u003cli\u003eEnhanced PPE for operatives\u003c\/li\u003e\n\u003cli\u003eExtended remediation consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Mould remediation in social housing requires H-Class dust extraction for disturbed mould — see the RUCKVAC HSV or MIDI HSV range. This kit provides the chemical treatment layer alongside H-Class vacuum extraction.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere this kit is used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eRefurbishment \u0026amp; void property works\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law (Social Housing Regulation Act 2023)\u003c\/a\u003e — Social landlords must investigate within 14 days, begin emergency repairs within 24 hours where there is immediate health risk, and complete remediation within 7 days. Written records required.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould spores are biological agents under COSHH. H-Class extraction mandatory where mould is disturbed. PPE mandatory throughout remediation.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/renting-homes-wales-act\"\u003eRenting Homes (Wales) Act 2016\u003c\/a\u003e — Continuous fitness standard requires freedom from damp, mould and condensation in all rented Welsh properties.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/awaabs-law-social-housing-maintenance-contractors\"\u003eAwaab's Law: what it means for social housing maintenance contractors →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/damp-mould-void-properties-social-housing\"\u003eDamp and mould in void properties: H-Class extraction and the correct remediation standard →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/communal-area-cleaning-high-rise-social-housing\"\u003eCommunal area cleaning in high-rise social housing →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/renting-homes-wales-act-maintenance-contractors\"\u003eRenting Homes (Wales) Act: what maintenance contractors need to know →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56081217028436,"sku":"MSP004","price":653.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MSP004_1.jpg?v=1781177774"},{"product_id":"pack-3-contractors-mould-remover-kit","title":"Pack 3: Contractors Mould Removal Kits","description":"\u003cp\u003e\u003cstrong\u003eA complete mould remediation kit — designed for compliant cleaning under Awaab's Law and COSHH.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack 3: Contractors Mould Remover Kit (MSP005)\u003c\/strong\u003e is the professional contractor-grade mould remediation kit for social housing maintenance teams, providing the full range of tools, removal products and PPE for compliant large-scale mould remediation in void and occupied social housing properties.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Social housing maintenance contractors, local authority DLO teams, and housing association operatives running systematic mould remediation programmes across multiple properties.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional-grade mould removal products\u003c\/li\u003e\n\u003cli\u003eFull contractor PPE set\u003c\/li\u003e\n\u003cli\u003eComplete remediation consumables for multi-property programmes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Full mould remediation programmes require H-Class dust extraction for all disturbed mould — see the RUCKVAC HSV or MIDI HSV range. This kit provides the chemical removal and PPE layer. H-Class vacuum extraction is a separate mandatory requirement under COSHH.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere this kit is used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eRefurbishment \u0026amp; void property works\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law (Social Housing Regulation Act 2023)\u003c\/a\u003e — Social landlords must investigate within 14 days, begin emergency repairs within 24 hours where there is immediate health risk, and complete all remediation within 7 days. Written records of all remediation work must be kept.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould spores are biological agents under COSHH Schedule 3. H-Class extraction is mandatory where mould is disturbed. Full PPE including respiratory protection is mandatory throughout. All operatives must be trained and assessed.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/renting-homes-wales-act\"\u003eRenting Homes (Wales) Act 2016\u003c\/a\u003e — Continuous fitness standard applies to all rented Welsh properties. Mould is a fitness for human habitation defect requiring remediation.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/social-housing-regulation-act\"\u003eSocial Housing (Regulation) Act 2023\u003c\/a\u003e — Awaab's Law provisions apply across all social housing in England.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/awaabs-law-social-housing-maintenance-contractors\"\u003eAwaab's Law: what it means for social housing maintenance contractors →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/damp-mould-void-properties-social-housing\"\u003eDamp and mould in void properties: H-Class extraction and the correct remediation standard →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/communal-area-cleaning-high-rise-social-housing\"\u003eCommunal area cleaning in high-rise social housing →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/renting-homes-wales-act-maintenance-contractors\"\u003eRenting Homes (Wales) Act: what maintenance contractors need to know →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56081224368468,"sku":"MSP005","price":1955.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MSP005_1.jpg?v=1781177862"},{"product_id":"vtuf-grindex1100lps-25l-110v","title":"V-TUF GRINDEX1100LPS H-Class Industrial Dust Extractor - 25L, 1150W - 110V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection for the finest, most hazardous dust on site.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1100LPS-110\u003c\/strong\u003e is a compact H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built to keep operators safe when vacuuming very fine, hazardous dust.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, tradespeople and industrial operators who need certified H-Class extraction when grinding, drilling, cutting or demolishing materials that release fine, hazardous dust.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 1150W | Voltage: 110V, 50\/60Hz | Amperage: 10A\u003c\/li\u003e\n\u003cli\u003eAirflow: 200 m³\/h | Max vacuum (depression): 250 mBar\u003c\/li\u003e\n\u003cli\u003eSuction inlet: Ø50mm tangential\u003c\/li\u003e\n\u003cli\u003eCapacity: 25L, Longopac® bagged collection system\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 48 × 44 × 104 cm | Weight: 25 kg\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: Ø330mm\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 10,000cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic reverse-flow system, differential-pressure triggered\u003c\/li\u003e\n\u003cli\u003eOptional secondary filter: HEPA H14 (99.995% @ 0.12μm), 11,200cm² surface\u003c\/li\u003e\n\u003cli\u003ePower tool socket: max 2200W, tool-start (PTO) system\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1100LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1100LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1100lps-troubleshooting\"\u003eGRINDEX1100LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1100lps-spare-parts\"\u003eGRINDEX1100LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384318767444,"sku":"GRINDEX1100LPS-110","price":2139.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1100LPS-110_1.jpg?v=1788426387"},{"product_id":"vtuf-grindex1100lps-25l-240v","title":"V-TUF GRINDEX1100LPS H-Class Industrial Dust Extractor - 25L, 1100W - 240V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection for the finest, most hazardous dust on site.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1100LPS-240\u003c\/strong\u003e is a compact H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built to keep operators safe when vacuuming very fine, hazardous dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors, tradespeople and industrial operators who need certified H-Class extraction when grinding, drilling, cutting or demolishing materials that release fine, hazardous dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 1100W | Voltage: 240V, 50\/60Hz | Amperage: 4.8A\u003c\/li\u003e\n\u003cli\u003eAirflow: 200 m³\/h | Max vacuum (depression): 250 mBar\u003c\/li\u003e\n\u003cli\u003eSuction inlet: Ø50mm tangential\u003c\/li\u003e\n\u003cli\u003eCapacity: 25L, Longopac® bagged collection system\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 48 × 44 × 104 cm | Weight: 25 kg\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: Ø330mm\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 10,000cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic reverse-flow system, differential-pressure triggered\u003c\/li\u003e\n\u003cli\u003eOptional secondary filter: HEPA H14 (99.995% @ 0.12μm), 11,200cm² surface\u003c\/li\u003e\n\u003cli\u003ePower tool socket: max 2200W, tool-start (PTO) system\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1100LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1100LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1100lps-troubleshooting\"\u003eGRINDEX1100LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1100lps-spare-parts\"\u003eGRINDEX1100LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384337903956,"sku":"GRINDEX1100LPS-240","price":2139.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1100LPS-110_1.jpg?v=1788426387"},{"product_id":"vtuf-grindex1200lps-2000w-110v","title":"V-TUF GRINDEX1200LPS H-Class Industrial Dust Extractor - 2000W - 110V","description":"\u003cp\u003e\u003cstrong\u003ePowerful, compact H-Class extraction for grinders, scarifiers and surface-prep tools — where fine, hazardous dust can't be allowed back into the air.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1200LPS (GRINDEX1200LPS-110)\u003c\/strong\u003e is a twin by-pass motor industrial dust extractor built for continuous, high-volume collection of hazardous fine dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e contractors and facilities teams running grinders, scarifiers, floor prep and other dust-generating tools where hazardous or fine dust must be captured at source.\u003c\/p\u003e\u003ch4\u003eKey Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMotor: 2 x by-pass motors\u003c\/li\u003e\n\u003cli\u003ePower: 2000W | Voltage: 110V - 60Hz | Max depression: 200mBar\u003c\/li\u003e\n\u003cli\u003eAirflow: 340 m³\/h\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 70 × 54 × 135 cm | Weight: 61 kg\u003c\/li\u003e\n\u003cli\u003eTank diameter: 370mm | Suction inlet: Ø50mm\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Fully automatic (reverse air-flow)\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 0.8m² filtering surface\u003c\/li\u003e\n\u003cli\u003eCertified class: H (hazardous dust)\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® continuous bagging, 22m\u003c\/li\u003e\n\u003cli\u003eProtection rating: IP54\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eImportant\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids — dry\/solid material collection only.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage on the rating plate (110V - 60Hz) before use.\u003c\/li\u003e\n\u003cli\u003eUse only genuine V-TUF filters and spare parts — non-approved parts can compromise safety and will void the warranty.\u003c\/li\u003e\n\u003cli\u003eNot for use in the presence of explosive or toxic gases, or for vacuuming explosive, incendiary, or flammable dusts and liquids.\u003c\/li\u003e\n\u003cli\u003eCheck filter condition and correct fitting before every use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003ch4\u003eWhere This Machine Is Used\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial Housing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLegislation That Applies\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine used to control hazardous fine dust, this extractor supports compliance with the Control of Substances Hazardous to Health Regulations, which require employers to assess and control exposure to hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, H-Class dust extractors like this one form part of the dust-control measures expected under the Construction (Design and Management) Regulations 2015.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction supports staying within the workplace exposure limits (WELs) set out in HSE guidance document EH40 for substances such as respirable crystalline silica.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e This machine's H-Class certification means it is suitable for use on tasks involving asbestos-containing materials, in line with CAR 2012 requirements — always confirm safe working procedures for any known or suspected asbestos before starting work.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e As with all machines used in commercial or industrial settings, this extractor should be maintained, inspected and operated in line with the Provision and Use of Work Equipment Regulations 1998.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where this machine is used on construction or refurbishment work inside healthcare settings, H-Class extraction supports compliance with Infection Control Risk Assessment requirements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation or associated dust control in social housing, H-Class extractors fall within the scope of Awaab's Law obligations on landlords.\u003c\/p\u003e\u003ch4\u003eFurther Reading\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSupport\u003c\/h4\u003e\u003cp\u003eNeed help with this machine? Visit our \u003ca href=\"\/pages\/grindex1200lps-troubleshooting\"\u003etroubleshooting guide\u003c\/a\u003e or \u003ca href=\"\/pages\/grindex1200lps-spare-parts\"\u003espare parts page\u003c\/a\u003e, or call us on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384716079444,"sku":"GRINDEX1200LPS-110","price":3637.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1200LP-110_1.jpg?v=1788426386"},{"product_id":"vtuf-grindex1200lps-2200w-240v","title":"V-TUF GRINDEX1200LPS H-Class Industrial Dust Extractor - 2200W - 240V","description":"\u003cp\u003e\u003cstrong\u003ePowerful, compact H-Class extraction for grinders, scarifiers and surface-prep tools — where fine, hazardous dust can't be allowed back into the air.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1200LPS (GRINDEX1200LPS-240)\u003c\/strong\u003e is a twin by-pass motor industrial dust extractor built for continuous, high-volume collection of hazardous fine dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e contractors and facilities teams running grinders, scarifiers, floor prep and other dust-generating tools where hazardous or fine dust must be captured at source.\u003c\/p\u003e\u003ch4\u003eKey Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMotor: 2 x by-pass motors\u003c\/li\u003e\n\u003cli\u003ePower: 2200W | Voltage: 230V - 50Hz | Max depression: 230mBar\u003c\/li\u003e\n\u003cli\u003eAirflow: 340 m³\/h\u003c\/li\u003e\n\u003cli\u003eDimensions (L×W×H): 70 × 54 × 135 cm | Weight: 61 kg\u003c\/li\u003e\n\u003cli\u003eTank diameter: 370mm | Suction inlet: Ø50mm\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Fully automatic (reverse air-flow)\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE cartridge, 0.8m² filtering surface\u003c\/li\u003e\n\u003cli\u003eCertified class: H (hazardous dust)\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® continuous bagging, 22m\u003c\/li\u003e\n\u003cli\u003eProtection rating: IP54\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eImportant\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids — dry\/solid material collection only.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage on the rating plate (230V - 50Hz) before use.\u003c\/li\u003e\n\u003cli\u003eUse only genuine V-TUF filters and spare parts — non-approved parts can compromise safety and will void the warranty.\u003c\/li\u003e\n\u003cli\u003eNot for use in the presence of explosive or toxic gases, or for vacuuming explosive, incendiary, or flammable dusts and liquids.\u003c\/li\u003e\n\u003cli\u003eCheck filter condition and correct fitting before every use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003ch4\u003eWhere This Machine Is Used\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial Housing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eLegislation That Applies\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine used to control hazardous fine dust, this extractor supports compliance with the Control of Substances Hazardous to Health Regulations, which require employers to assess and control exposure to hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, H-Class dust extractors like this one form part of the dust-control measures expected under the Construction (Design and Management) Regulations 2015.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction supports staying within the workplace exposure limits (WELs) set out in HSE guidance document EH40 for substances such as respirable crystalline silica.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e This machine's H-Class certification means it is suitable for use on tasks involving asbestos-containing materials, in line with CAR 2012 requirements — always confirm safe working procedures for any known or suspected asbestos before starting work.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e As with all machines used in commercial or industrial settings, this extractor should be maintained, inspected and operated in line with the Provision and Use of Work Equipment Regulations 1998.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where this machine is used on construction or refurbishment work inside healthcare settings, H-Class extraction supports compliance with Infection Control Risk Assessment requirements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation or associated dust control in social housing, H-Class extractors fall within the scope of Awaab's Law obligations on landlords.\u003c\/p\u003e\u003ch4\u003eFurther Reading\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSupport\u003c\/h4\u003e\u003cp\u003eNeed help with this machine? Visit our \u003ca href=\"\/pages\/grindex1200lps-troubleshooting\"\u003etroubleshooting guide\u003c\/a\u003e or \u003ca href=\"\/pages\/grindex1200lps-spare-parts\"\u003espare parts page\u003c\/a\u003e, or call us on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56384721617236,"sku":"GRINDEX1200LPS-240","price":3637.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1200LP-110_1.jpg?v=1788426386"},{"product_id":"vtuf-grindex1300lps-3300w-110v","title":"V-TUF GRINDEX1300LPS H-Class Industrial Dust Extractor - 3300W, 450m³\/h - 110V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection built for the toughest industrial dust extraction jobs.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1300LPS-110\u003c\/strong\u003e is a high-capacity, three-motor H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built for continuous operation with surface preparation machinery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors and industrial operators running grinders, scarifiers, sanders and shot blasters who need certified H-Class extraction for very fine, hazardous dust over extended shifts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 3300W total | Voltage: 110V, 60Hz\u003c\/li\u003e\n\u003cli\u003eMotor: 3× by-pass motors\u003c\/li\u003e\n\u003cli\u003eAirflow: 450 m³\/h | Max vacuum (depression): 200 mBar\u003c\/li\u003e\n\u003cli\u003eTangential suction inlet\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE, 3× cartridge, 20,500cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic, continuous-suction reverse-flow system\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® 22m continuous bag, optional 100L tank\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: 460mm\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1300LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1300LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1300lps-troubleshooting\"\u003eGRINDEX1300LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1300lps-spare-parts\"\u003eGRINDEX1300LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56385125810516,"sku":"GRINDEX1300LPS-110","price":5389.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1300LPS_1.jpg?v=1783504545"},{"product_id":"vtuf-grindex1300lps-3300w-240v","title":"V-TUF GRINDEX1300LPS H-Class Industrial Dust Extractor - 3300W, 510m³\/h - 240V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection built for the toughest industrial dust extraction jobs.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1300LPS-240\u003c\/strong\u003e is a high-capacity, three-motor H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built for continuous operation with surface preparation machinery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors and industrial operators running grinders, scarifiers, sanders and shot blasters who need certified H-Class extraction for very fine, hazardous dust over extended shifts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 3300W total | Voltage: 230V, 50Hz\u003c\/li\u003e\n\u003cli\u003eMotor: 3× by-pass motors\u003c\/li\u003e\n\u003cli\u003eAirflow: 510 m³\/h | Max vacuum (depression): 230 mBar\u003c\/li\u003e\n\u003cli\u003eTangential suction inlet\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE, 3× cartridge, 20,500cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic, continuous-suction reverse-flow system\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® 22m continuous bag, optional 100L tank\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: 460mm\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1300LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1300LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1300lps-troubleshooting\"\u003eGRINDEX1300LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1300lps-spare-parts\"\u003eGRINDEX1300LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56385132429652,"sku":"GRINDEX1300LPS-240","price":5389.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1300LPS_1.jpg?v=1783504545"},{"product_id":"v-tuf-aeromax800-air-scrubber-110v","title":"V-TUF AEROMAX800 Air Scrubber - 700CFM, H13 HEPA - 110V","description":"\u003cp\u003e\u003cstrong\u003eA high-performance portable air scrubber that captures airborne dust, mould spores and fine particulates to protect indoor air quality on restoration and construction sites.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX800\u003c\/strong\u003e (SKU: AEROMAX800-110) is a professional air filtration system for mould remediation, water-damage restoration and dust control, drawing air through multi-stage filtration at up to 700 CFM.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Restoration and construction professionals who need continuous, high-volume air filtration to control airborne contaminants and improve indoor air quality.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximum airflow: 700 CFM (19.8 m³\/min)\u003c\/li\u003e\n\u003cli\u003eRecommended for spaces of 100–170 m³\u003c\/li\u003e\n\u003cli\u003eFiltration: multi-stage — G4 pre-filter + H13 HEPA filter (99.95%)\u003c\/li\u003e\n\u003cli\u003eVariable stepless speed control\u003c\/li\u003e\n\u003cli\u003eDaisy-chain capable — two external sockets to run multiple units from one supply\u003c\/li\u003e\n\u003cli\u003eMotor speed: 2,450 RPM\u003c\/li\u003e\n\u003cli\u003eRugged rotomoulded housing\u003c\/li\u003e\n\u003cli\u003eDimensions: 61 × 35 × 56 cm | Weight: 15.0 kg\u003c\/li\u003e\n\u003cli\u003ePower supply: 110V \/ 50Hz (transformer supply)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e Activated carbon filter or HEPA + carbon combination for odour and VOC removal; optional UV-C module for enhanced biological sterilisation (sold separately).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1× V-TUF AEROMAX800 air scrubber with G4 pre-filter and H13 HEPA filter fitted\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Tool-free filter changes via heavy-duty hasps. Requires a 110V transformer supply. Position the unit for effective air circulation across the work area and replace filters in line with dust loading.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; site work\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing — damp \u0026amp; mould remediation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; infection control\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e:\u003c\/strong\u003e Employers must control exposure to hazardous airborne substances. High-volume HEPA air filtration helps reduce airborne dust and contaminant concentrations at the work area.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e:\u003c\/strong\u003e On construction, refurbishment and demolition projects, dust and air-quality controls form part of managing site health risks under the Construction (Design and Management) Regulations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e:\u003c\/strong\u003e Air filtration supports keeping airborne dust below the workplace exposure limits set out in EH40, alongside extraction at source.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012\u003c\/a\u003e:\u003c\/strong\u003e Where used to filter air within an asbestos enclosure, a HEPA unit can form part of the controls under CAR 2012 — subject to a suitable risk assessment and, where applicable, licensed working.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e:\u003c\/strong\u003e For social-housing damp and mould remediation, air scrubbers support the timely, effective remediation expected under Awaab's Law.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/icra\"\u003eICRA\u003c\/a\u003e:\u003c\/strong\u003e In healthcare settings, HEPA air filtration supports Infection Control Risk Assessment requirements during construction or refurbishment near patient areas.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/understanding-asbestos\"\u003eUnderstanding asbestos: health risks, causes and solutions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/combat-risks-hazardous-construction-dust\"\u003eCombating the risks of hazardous construction dust\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56709108171092,"sku":"Aeromax800-110","price":839.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/AEROMAX800-2-DRAFT_b7cef198-f0e8-4a98-94be-3bf9a7e99920.jpg?v=1786103704"},{"product_id":"v-tuf-aeromax800-air-scrubber-240v","title":"V-TUF AEROMAX800 Air Scrubber - 700CFM, H14 HEPA - 240V","description":"\u003cp\u003e\u003cstrong\u003eA high-performance portable air scrubber that captures airborne dust, mould spores and fine particulates to protect indoor air quality on restoration and construction sites.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eV-TUF AEROMAX800\u003c\/strong\u003e (SKU: AEROMAX800-240) is a professional air filtration system for mould remediation, water-damage restoration and dust control, drawing air through multi-stage filtration at up to 700 CFM.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Restoration and construction professionals who need continuous, high-volume air filtration to control airborne contaminants and improve indoor air quality.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximum airflow: 700 CFM (19.8 m³\/min)\u003c\/li\u003e\n\u003cli\u003eRecommended for spaces of 100–170 m³\u003c\/li\u003e\n\u003cli\u003eFiltration: multi-stage — G4 pre-filter + H14 HEPA filter (99.995%)\u003c\/li\u003e\n\u003cli\u003eVariable stepless speed control\u003c\/li\u003e\n\u003cli\u003eDaisy-chain capable — two external sockets to run multiple units from one supply\u003c\/li\u003e\n\u003cli\u003eMotor speed: 2,450 RPM\u003c\/li\u003e\n\u003cli\u003eRugged rotomoulded housing\u003c\/li\u003e\n\u003cli\u003eDimensions: 61 × 35 × 56 cm | Weight: 15.0 kg\u003c\/li\u003e\n\u003cli\u003ePower supply: 240V \/ 50Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e Activated carbon filter or HEPA + carbon combination for odour and VOC removal; optional UV-C module for enhanced biological sterilisation (sold separately).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1× V-TUF AEROMAX800 air scrubber with G4 pre-filter and H14 HEPA filter fitted\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Tool-free filter changes via heavy-duty hasps. Position the unit for effective air circulation across the work area and replace filters in line with dust loading.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; site work\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing — damp \u0026amp; mould remediation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; infection control\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e:\u003c\/strong\u003e Employers must control exposure to hazardous airborne substances. High-volume HEPA air filtration helps reduce airborne dust and contaminant concentrations at the work area.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e:\u003c\/strong\u003e On construction, refurbishment and demolition projects, dust and air-quality controls form part of managing site health risks under the Construction (Design and Management) Regulations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40 Workplace Exposure Limits\u003c\/a\u003e:\u003c\/strong\u003e Air filtration supports keeping airborne dust below the workplace exposure limits set out in EH40, alongside extraction at source.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012\u003c\/a\u003e:\u003c\/strong\u003e Where used to filter air within an asbestos enclosure, an H14 HEPA unit can form part of the controls under CAR 2012 — subject to a suitable risk assessment and, where applicable, licensed working.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/awaabs-law\"\u003eAwaab's Law\u003c\/a\u003e:\u003c\/strong\u003e For social-housing damp and mould remediation, air scrubbers support the timely, effective remediation expected under Awaab's Law.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/icra\"\u003eICRA\u003c\/a\u003e:\u003c\/strong\u003e In healthcare settings, HEPA air filtration supports Infection Control Risk Assessment requirements during construction or refurbishment near patient areas.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/understanding-asbestos\"\u003eUnderstanding asbestos: health risks, causes and solutions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/combat-risks-hazardous-construction-dust\"\u003eCombating the risks of hazardous construction dust\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on +44 (0)1522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56709108236628,"sku":"Aeromax800-240","price":839.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/AEROMAX800-2-DRAFT_b7cef198-f0e8-4a98-94be-3bf9a7e99920.jpg?v=1786103704"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/collections\/awaabs-law-phase-2-hero-image.png?v=1791797383","url":"https:\/\/www.v-tuf.co.uk\/collections\/awaabs-law-compliant-equipment.oembed","provider":"V-TUF","version":"1.0","type":"link"}